Venous occlusion and estimation of serum constituents.
Crombie IK, Smith WC, Tavendale RT, Clark EC, Tunstall-Pedoe HD
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of tourniquet time and tourniquet pressure on total cholesterol, HDL cholesterol, GGT, triglycerides, creatinine, thiocyanate, uric acid, and glucose in serum. Either a blood pressure cuff or a Velcro tourniquet was used, and specimens were withdrawn sequentially at time 0 (before venous occlusion), and after 1, 2, and 3 min of venous occlusion. The first 1.5 mL was discarded at each time point. The authors do not give details about serum preparation or storage prior to analysis.
Summary of Findings
No significant differences in any of the 8 serum constituents were noted when a blood pressure cuff was applied at 20 mm Hg for 1, 2, or 3 minutes prior to blood draw or when a Velcro tourniquet was used compared to the levels measured in specimens drawn with no venous occlusion. However, when the blood pressure cuff was applied at 40 mm Hg for 3 min during specimen collection, significant increases in HDL cholesterol (+7.11%), total cholesterol (+5.71%), GGT (+4.15%), and triglycerides (+3.96%), as well as significant decreases in glucose levels (-4.70%) were measured compared to levels measured in specimens drawn prior to venous occlusion. These trends were linear during 1-3 min of venous occlusion. Creatinine, thiocyanate, and uric acid were not significantly affected by venous occlusion at any pressure or for any duration tested.
Biospecimens
FluidSerumFluidBloodPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
SteroidClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerLipidClinical chemistry/auto analyzerSmall moleculeClinical chemistry/auto analyzerCarbohydrateClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Method of fluid acquisition Tourniquet pressures comparedTourniquet times compared