Implementation of a proficiency testing for the assessment of the preanalytical phase of blood samples used for RNA based analysis.

Günther K, Malentacchi F, Verderio P, Pizzamiglio S, Ciniselli CM, Tichopad A, Kubista M, Wyrich R, Pazzagli M, Gelmini S

Publication: Clin Chim Acta (2012) • Vol 413 • Page 779-86PMID: 22285774View on PubMed

Purpose

The purpose of this paper was to determine the effects PAXgene blood stabilization and delayed RNA extraction due to room temperature storage or shipment on RNA integrity and gene expression.

Conclusion

RNA integrity numbers (RIN) tended to be lower and more variable in specimens collected in EDTA tubes rather than PAXgene tubes, and this variability increased when RNA extraction was delayed due to storage at room temperature for 2 h or overnight shipment. Further, while storage at room temperature for 2 h or overnight shipment at ambient temperatures had little effect on gene expression in specimens stored in PAXgene tubes, storage of blood in EDTA tubes resulted in an increase in the variability of expression data. There was no effect of shipping RNA twice rather than once on RNA integrity, yield or gene expression.

Studies (2)

Purpose

The purpose of this study was to determine the effects of PAXgene blood stabilization and a 2 h delay in RNA extraction on RNA integrity and expression. After preparation, RNA was shipped on dry ice. RNA was isolated from specimens in PAXgene tubes using PAXgene system and from specimens in EDTA tubes by a standard protocol (phenol and or column based protocols).

Summary of Findings

Much lower minimum RIN were observed in RNA obtained from specimens collected in EDTA tubes than from specimens collected in PAXgene tubes. While the median RIN for RNA obtained from specimens collected in EDTA or PAXgene tubes and not stored or in PAXgene tubes and stored for 2 h at room temperature was >8, the median RIN in RNA from specimens stored for 2 h at room temperature in EDTA tubes was 3.1 and only 2/7 had RIN >8. The effect of delayed extraction of RNA from PAXgene blood on the expression of glyceraldehyde 3-phosphate dehydrogenase (GAPDH), interleukin (IL)8, IL1B, and FBJ murine osteosarcoma viral oncogene homolog (FOS) was small, but differences in expression of GAPDH, IL8, IL1B and FOS between RNA from EDTA tubes that were extracted immediately rather than stored at room temperature for 2 h before extraction were large and highly variable.

  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)PAXgene
  • Diagnoses

    Normal
  • Platforms

    RNAAutomated electrophoresis/Bioanalyzer
    RNAReal-time qRT-PCR
    RNASpectrophotometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionType of collection container/solution
    EDTA tube
    PAXgene tube
    Biospecimen PreservationType of fixation/preservation
    None (fresh)
    PAXgene
    StorageStorage duration
    0 h
    2 h
    Real-time qRT-PCR SpecificTargeted nucleic acid
    FOS
    GAPDH
    IL1B
    IL8