Calculating acid-base and oxygenation status during COPD exacerbation using mathematically arterialised venous blood.
Rees SE, Rychwicka-Kielek BA, Andersen BF, Bibi R, Pedersen JF, Weinreich UM, Birket-Smith LB, Kristensen SR
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of arterial versus venous blood collection for the measurement of pH, PCO2, and PO2 in specimens from patients with COPD. The difference between measured arterial blood gas values and those calculated from peripheral venous values was evaluated. Venous and arterial specimens were collected into PICO50 syringes and PICO70 syringes, respectively, within a few minutes of one another.
Summary of Findings
Very strong correlations (r2=0.96 and r2=0.98) and no significant differences in pH and PCO2, respectively, were observed between actual arterial blood gas levels and arterial values that were calculated using peripheral venous values, while a modest correlation (r2=0.63) and no significant difference was observed between measured and calculated PO2 values in arterial blood. Correlations between measured arterial and venous pH, PCO2, and PO2 levels were relatively weaker at r2=0.83, r2=0.90, and r2=0.01, respectively. The maximum changes in arterial pH, PCO2, and PO2 over the COPD patients' stays in the hospital were not significantly different from the maximum changes in calculated arterial pH, PCO2, and PO2. The authors conclude that calculated values of arterial pH, PCO2, and PO2 are a reliable alternative to measured values for tracking COPD patient status, while venous values alone are not.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
Chronic Obstructive Pulmonary Disease (COPD)Platforms
GasRadiometerElectrolyte/MetalRadiometerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anatomical location of blood draw ArteryVeinBiospecimen Acquisition Time of biospecimen collection Day 1Day 2Day 3Day 4Day 5Day 6