Skip to main content

Role of training activities for the reduction of pre-analytical errors in laboratory samples from primary care.

Romero A, Cobos A, Gómez J, Muñoz M

Publication: Clin Chim Acta (2012) • Vol 413 • Page 166-9PMID: 21964461View on PubMed

Purpose

The purpose of this paper was to determine the effects of education in proper phlebotomy technique for nursing staff on the incidence of hemolysis, coagulation, and other pre-analytical errors in specimen collection that precluded analysis.

Conclusion

After an educational intervention for nurses covering proper techniques for blood collection, the percentage of hemolyzed specimens received by the laboratory significantly increased, but the percentage of coagulated specimens received by the laboratory decreased. The percentage of specimens received with incorrect specimen volume did not significantly change after the training, and the percentage of specimens with other pre-analytical errors such as lipemic or icteric serum or plasma increased slightly.

Studies (1)

Purpose

The purpose of this study was to determine the effects of education in phlebotomy technique for nursing staff on the incidence of hemolysis, coagulation, incorrect specimen volume, or lipemic or icteric serum or plasma that precluded analysis.

Summary of Findings

After an educational intervention for nurses consisting of a one-hour session covering proper techniques for blood collection, peculiarities, causes of analytical interference, and specimen delivery from primary care facilities to the hospital laboratory, the percentage of hemolyzed specimens received by the laboratory significantly increased from 1.97% to 3.90% (p<0.001). At the same time, the percentage of coagulated specimens received by the laboratory decreased from 0.54% to 0.25% (p<0.001). The percentage of specimens received with incorrect specimen volume did not significantly change after the training. The percentage of specimens with other pre-analytical errors such as lipemic or icteric serum or plasma increased from 0.30% to 0.42% (p<0.001) after training.

  • Biospecimens

    FluidBlood
    FluidPlasma
    FluidSerum
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Cell count/volumeMacroscopic observation
    Cell count/volumeHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionMethod of fluid acquisition
    Staff trained/experienced in phlebotomy
    Staff untrained/inexperienced in phlebotomy