Homocysteine stability in heparinized plasma stored in a gel separator tube.
Calam RR, Mansoor I, Blaga J
Purpose
Conclusion
Studies (2)
Purpose
The purpose of this study was to determine the effects of collection tube type, frozen storage of plasma in PST, and post-thaw refrigerated storage duration on the stability of Hcy in plasma. After centrifugation, EDTA-plasma was transferred to a new tube while heparinized plasma was left on the gel in the original PST. All specimens were frozen at -20 degrees C for an undisclosed amount of time. Specimens were then thawed at room temperature, assayed, and then placed in a refrigerator (2-8 degrees C) for a specified amount of time before reassaying.
Summary of Findings
Hcy levels were significantly higher in frozen heparinized plasma that had been kept on the gel barrier in PST than in EDTA plasma that was transferred to a new tube prior to freezing. Once thawed, Hcy was stable in both types of specimens when refrigerated for 2 days, but values decreased by 12.2 and 15% in EDTA plasma and heparinized plasma, respectively, after 5 days of post-thaw refrigerated storage.
Biospecimens
FluidPlasmaFluidBloodPreservation Types
FrozenDiagnoses
NormalPlatforms
Small moleculeClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anticoagulant EDTAHeparinBiospecimen Acquisition Type of collection container/solution EDTA tubePST with gel separatorStorage Storage duration 0 d2 d5 dStorage Type of storage container New tubeOriginal PST
Purpose
The purpose of this study was to determine the effects of collection and storage tube type and refrigerated storage duration on the stability of Hcy in plasma. After centrifugation, EDTA-plasma was transferred to a new tube while heparinized plasma was left on the gel in the original PST.
Summary of Findings
Similar levels of Hcy were observed after 2-3 days of refrigerated storage (2-8 degrees C) of either EDTA-plasma in a new tube or heparinized plasma on the gel barrier in the original PST.
Biospecimens
FluidPlasmaFluidBloodPreservation Types
Other PreservativeDiagnoses
NormalPlatforms
Small moleculeClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anticoagulant EDTAHeparinBiospecimen Acquisition Type of collection container/solution EDTA tubePST with gel separatorStorage Storage duration 0 d2 d3 dStorage Type of storage container New tubeOriginal PST