Skip to main content

Effect of sample tube type and time to separation on in vitro levels of C-reactive protein.

Anderson NR, Chatha K, Holland MR, Gama R

Publication: Br J Biomed Sci (2003) • Vol 60 • Page 164-5PMID: 14560795View on PubMed

Purpose

The purpose of this paper was to determine the effects of collection tube type and delayed centrifugation on the stability of C-reactive protein (CRP) in serum and plasma.

Conclusion

CRP levels were significantly higher in specimens collected in gel tubes than in plain or EDTA tubes when specimens were centrifuged within 20 min, but no differences were observed between tube types with longer delays prior to centrifugation. Room temperature delays prior to centrifugation did not significantly affect CRP levels in specimens in plain or EDTA tubes, however, CRP levels significantly decreased after 8 and 24 h delays prior to centrifugation for specimens in gel tubes compared to levels measured in specimens centrifuged within 20 min.

Studies (1)

Purpose

The purpose of this study was to determine the effects of collection tube type and delayed centrifugation on the stability of CRP in serum and plasma from 7 patients with chronic renal failure. Specimens were transported to the laboratory on ice but then remained at room temperature while aliquots were removed and centrifuged after each experimental delay. Supernatant was frozen at -20 degrees C until analysis.

Summary of Findings

CRP levels were significantly higher in specimens collected in gel tubes than in plain or EDTA tubes when specimens were centrifuged within 20 min (both p<0.05), but no differences were observed between tube types with longer delays prior to centrifugation. Room temperature delays prior to centrifugation did not significantly affect CRP levels in specimens collected in plain or EDTA tubes, however, CRP levels significantly decreased after 8 and 24 h delays prior to centrifugation in specimens in gel tubes (both p<0.05) compared to levels measured in specimens centrifuged within 20 min.

  • Biospecimens

    FluidPlasma
    FluidSerum
    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    Other diagnoses
  • Platforms

    ProteinImmunoassay
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Chronic renal failure
    Biospecimen AcquisitionType of collection container/solution
    EDTA tube
    Gel tube
    Plain glass tube
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Serum
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    StorageTime at room temperature
    1 h
    2 h
    20 min
    24 h
    4 h
    8 h