Skip to main content

Coamplification of HIV-1 proviral DNA and viral RNA in assays used for quantification of HIV-1 RNA.

Wan H, Seth A, Rainen L, Fernandes H

Publication: J Clin Microbiol (2010) • Vol 48 • Page 2186-90PMID: 20181913View on PubMed

Purpose

The purpose of this paper was to determine the effects of collection and storage tube type on human immunodeficiency virus (HIV) load in plasma.

Conclusion

HIV viral loads in plasma were higher when specimens were collected and stored in plasma preparation tubes (PPTs) rather than when blood was collected in EDTA vacutainers and plasma was transferred to a new tube before freezing. Proviral DNA contributed to the viral load in specimens collected using both tube types, but the contribution of proviral DNA to viral load was much larger when specimens were collected and stored in PPT rather than EDTA vacutainers with storage of separated plasma in a new tube.

Studies (1)

Purpose

The purpose of this study was to determine the effects of collection and storage tube type on HIV load determination in plasma using a Roche COBAS Amplicor HIV-1 Monitor version 1.5. From each patient, blood was collected into EDTA vacutainers and PPT tubes and centrifuged within 2 h as appropriate. After centrifugation, EDTA-plasma was transferred to a new tube before freezing at -70 degrees C, while plasma in the PPT was frozen at -70 degrees C in the collection tube.

Summary of Findings

While all 50 specimens collected and stored in PPT had detectable HIV loads, 14 of the 50 matched EDTA-plasma specimens had viral loads below the limit of detection. Further, the mean viral load in the 28 specimens with viral loads of 50-1000 copies/mL was 419 copies/mL in EDTA-plasma and 815 copies/mL in plasma collected and stored in PPTs (p=0.002). After destruction of the RNA through heat inactivation, 77% of HIV load was still detected in EDTA-plasma, and 58% was still detected in PPT tubes. After DNAse I treatment 93.7% of the viral load was detected in EDTA-plasma and 59.9% of the viral load was still detected in PPT tubes, indicating DNA is contributing to viral load determination in a collection tube-dependent manner. There were no differences in genomic DNA concentrations between EDTA-plasma and plasma collected and stored in PPT tubes.

  • Biospecimens

    FluidPlasma
    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    AIDS/HIV-related
  • Platforms

    RNART-PCR
    DNAPCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionBiomarker level
    1000-2500 copies HIV-1/mL
    3000-5000 copies HIV-1/mL
    50-1000 copies HIV-1/mL
    <50 copies HIV-1/mL
    Biospecimen AcquisitionType of collection container/solution
    EDTA vacutainer
    PPT
    StorageType of storage container
    New tube
    PPT tube
    Analyte Extraction and PurificationNucleic acid digestion
    DNAse
    Heat-treatment
    None