Determination of hemolysis thresholds by the use of data loggers in pneumatic tube systems.
Streichert T, Otto B, Schnabel C, Nordholt G, Haddad M, Maric M, Petersmann A, Jung R, Wagener C
Purpose
The purpose of this paper was to determine the effects of transporting specimens via pneumatic tube system (PTS) and PTS speed on 42 clinical chemistry and hematological analytes in blood.
Conclusion
After PTS at 2.5 m/s potassium (K), phosphate, aspartate aminotransferase (ASAT) and lactate dehydrogenase (LDH) increased beyond the allowance of the guidelines of the German Federal Medical Council. The magnitude of the changes decreased with decreasing transport speed. The changes in LDH, ASAT and K were correlated with hemolysis which also increased with increasing transport speed.
Studies (1)
Purpose
The purpose of this study was to determine the effects of transporting specimens via PTS and PTS speed on 42 clinical chemistry and hematological analytes in blood. Specimens were collected into K EDTA, coagulation, or ammonium heparin tubes, serum monovettes, or PICO samplers as appropriate. Transport by PTS and hand-delivery took 5-6.5 min and 7.5 min, respectively and there were no difference in specimen transport, humidity or pressure during transport, but significant differences in 3-axis acceleration occurred.
Summary of Findings
PTS transport at 2.5 m/s significantly affected platelet and monocyte counts, reptilase time, D-dimer fragments, antithrombin, K, phosphorus, magnesium, ASAT, alanine aminotransferase (ALAT), lipase, and LDH levels, but only the increases in K, phosphate ASAT and LDH exceeded the allowance of the guidelines of the German Federal Medical Council. The magnitude of the changes, which were not always directionally consistent, decreased with decreasing transport speed, and, at a speed of 1.5 m/s, only the increases in LDH and ASAT were significant and exceeded the guideline allowances. None of the other 43 analytes were affected. The changes in LDH, ASAT and K were correlated with hemolysis, which also increased with increasing transport speed.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
Electrolyte/MetalClinical chemistry/auto analyzerGasClinical chemistry/auto analyzerPeptideClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerCarbohydrateClinical chemistry/auto analyzerSmall moleculeClinical chemistry/auto analyzerCell count/volumeHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Specimen transport duration/condition 1.5 m/s2.0 m/s2.5 m/sStorage Within hospital transportation method Hand-deliveredPneumatic tube system