Effect of posture on the plasma cholesterol level.
Stoker DJ, Wynn V, Robertson G
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of patient posture and use of venous compression during blood collection on plasma cholesterol, protein, hematocrit, and calcium. Blood was drawn into lithium heparin tubes commencing after patients maintained a horizontal position for at least 1 hour, and a second specimen was drawn 15 minutes later. Then patients walked slowly for 15 minutes before a third specimen was drawn. A fourth specimen was drawn while patients remained standing but had a tourniquet applied for 2 minutes. A separate set of 6 specimens was drawn commencing after patients had been walking for at least one hour, followed by the patients laying down and specimens being drawn every 5 minutes for 25 minutes.
Summary of Findings
Upon standing from a supine position, plasma cholesterol levels increased by an average of 12.9% in specimens from both normal patients and those with hypercholesterolaemia. At the same time, plasma protein levels significantly increased by an average of 8.5%, hematocrit increased an average of 8.6%, and plasma calcium levels increased by an average of 6.7%. The use of a sphygmomanometer led to further insignificant increases in cholesterol and plasma protein levels in the majority of patients and significant increases in hematocrit for the majority of patients. The authors do not provide statistical analysis for changes in calcium levels after application of a sphygmomanometer, but 3 of 5 individuals showed slight decreases, while the other 2 showed slight increases. When patients assumed a supine position after 1 hour of standing, cholesterol and protein levels and hematocrit significantly decreased, returning to basal levels after 20 minutes in a supine position for most individuals.
Biospecimens
FluidPlasmaFluidBloodPreservation Types
None (Fresh)Diagnoses
NormalOther diagnosesPlatforms
Cell count/volumeHematology/ auto analyzerSteroidClinical chemistry/auto analyzerElectrolyte/MetalClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Biomarker level 3.00 mg/mL or more<3.00 mg/mLPreaquisition Diagnosis/ patient condition HypercholesterolaemiaBiospecimen Acquisition Method of fluid acquisition Tourniquet times comparedBiospecimen Acquisition Patient posture StandingSupineBiospecimen Acquisition Time of biospecimen collection 10 min15 min20 min25 min5 minTime 0