The stability of blood, plasma and serum constituents during simulated transport.
Felding P, Petersen PH, Hørder M
Purpose
Conclusion
Studies (2)
Purpose
The purpose of this study was to determine the effects of storage for 4 days at 20, 4, and -20 degrees C, rotation for 5 h, shaking for 1 h or heating to 50 degrees C for 1 h prior to storage, and an additional thawing of specimens stored at -20 degrees C on levels of clinical chemistry analytes in serum, glucose and coagulation factors in plasma, and hematology parameters in blood. Specimens for all analytes except glucose were stabilized with sodium citrate, but for glucose, plasma was stabilized with heparin sodium fluoride.
Summary of Findings
Storage for 4 days at 20 degrees C led to a 10% decrease in serum iron levels, a 16% increase in plasma coagulation factors II, VII and X by the OWREN analyzer and an unspecified increase in plasma coagulation factors II, V, VIII, IX and XII when determined by ACT levels relative to initial levels. Storage for 4 days at 4 degrees C led to an 8.7% decrease in serum iron levels and a 13% increase in plasma coagulation factors by ACT relative to initial levels. After 4 days at -20 degrees C, levels of iron in serum were increased 6.8%. When there was an additional thawing for 1 h at room temperature during the 4 days of storage at -20 degrees C, all analyte levels remained within one CV of initial levels. When serum was subjected to 5 h of rotation at room temperature prior to 4 days of storage at -20 degrees C, levels of iron, ASAT, and bilirubin in serum increased 21%, 36%, and 8.8%, respectively, and plasma coagulation factors measured by OWREN decreased 25% relative to initial levels. However, when serum was subjected to 1 h of shaking prior to storage at -20 degrees C, levels of all analytes remained within one CV of initial levels. When serum was heated to 50 degrees C for 1 h and then stored for 4 days at -20 degrees C, ALP, creatinine kinase and plasma coagulation factors (measured by OWREN) decreased by 36%, 69% and 52%, respectively. All other analytes remained within the CV of initial values, regardless of storage temperature or pre-storage treatments.
Biospecimens
FluidBloodFluidPlasmaFluidSerumPreservation Types
None (Fresh)FrozenOther PreservativeDiagnoses
NormalPlatforms
Electrolyte/MetalClinical chemistry/auto analyzerGlycoproteinClinical chemistry/auto analyzerGlycoproteinRadioimmunoassaySmall moleculeClinical chemistry/auto analyzerSteroidClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerPeptideRadioimmunoassayCarbohydrateEnzyme assayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Biospecimen mixing No shaking or rotationWith rotation at 40 rpm for 5 hWith shaking at 10 Hz for 1 hBiospecimen Preservation Type of fixation/preservation FrozenNone (fresh)RefrigerationStorage Freeze/thaw cycling 1 cycle2 cyclesStorage Storage temperature -20 degrees C20 degrees C4 degrees C50 degrees C
Purpose
The purpose of this study was to determine the effects of storage for 4 days at 4 degrees C, with or without rotation for 5 h, shaking for 1 h, heating to 50 degrees C for 1 h, or freezing at -20 degrees C and thawing at room temperature prior to 4 degrees C storage on hematology parameters in blood. Specimens were stabilized with sodium EDTA.
Summary of Findings
Storage at 4 degrees C for 4 days led to a 28% decrease in thrombocyte counts. When specimens were frozen at -20 degrees C prior to storage at 4 degrees C, thrombocyte, leukocyte, and erythrocyte counts decreased by 53%, 25% and 9.5%, respectively, and hematocrit increased by 10% relative to initial levels. Specimens that were heated to 50 degrees C for 1 h prior to storage at 4 degrees C had 382%, 8.6%, 5.5% and 5.8% increases in leukocyte counts, erythrocyte counts, hemoglobin levels, and hematocrit, respectively. None of the analytes were significantly different from initial levels when shaken for 1 h or rotated for 5 h prior to storage for 4 days at 4 degrees C.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Other PreservativeDiagnoses
NormalPlatforms
Cell count/volumeHematology/ auto analyzerProteinHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Biospecimen mixing With no shaking or rotationWith rotation at 40 rpm for 5 hWith shaking at 10 Hz for 1 hBiospecimen Preservation Type of fixation/preservation None (fresh)RefrigerationStorage Freeze/thaw cycling 0 cycles1 cycleStorage Storage temperature -20 degrees C4 degrees C50 degrees C