Spurious laboratory values resulting from simulated mailing conditions. A study of time and temperature variables.
Baer DM, Krause RB
Purpose
Conclusion
Studies (3)
Purpose
The purpose of this study was to determine the effects of serum storage temperature and duration on calcium, cholesterol, creatinine, GOT, T3 uptake, and electrophoretic fractions.
Summary of Findings
Calcium levels in serum stored in tubes with a cork stopper were significantly increased after storage at 4 degrees C for 3 days or more or storage for 1 day at room temperature or 37 degrees C. In contrast, when tubes were sealed with rubber stoppers, storage duration and temperature had no significant effects on calcium levels. Importantly, a precipitate that prevented measurement of calcium appeared in specimens stored in cork-stoppered tubes at 25 degrees C for 4 days or longer or 37 degrees C for 2 days or more as well as in specimens stored in rubber-stoppered tubes at 4 degrees C or room temperature for 7 days or at 37 degrees C for 4 days or more. Cholesterol and creatinine levels were not affected by storage for 7 days at any temperature and stopper types were not compared. GOT levels decreased with storage at 37 degrees C for 2 days or more in specimens with high initial levels of GOT, but levels were not significantly changed after storage for 7 days at room temperature or 4 degrees C. In specimens with normal GOT levels, the authors report small absolute changes that were large when considered by percentage change, but the values and significance were not discussed. T3 uptake was unaffected by storage of serum at 4 degrees C or room temperature for 7 days but was increased after 1 day of storage between 30-40 degrees C, reaching clinical hyperthyroid levels after 4 days of storage at these higher than ambient temperatures. In serum stored at 35-46 degrees C, the alpha 1 and 2 globin bands were fused starting at day 1, but there was no change in the percentage of albumin or beta or gamma globin. Rh factor antibody titers were stable in serum stored for 7 days at 4, 24, or 37 degrees C.
Biospecimens
FluidSerumPreservation Types
None (Fresh)Other PreservativeDiagnoses
Not specifiedPlatforms
PeptideClinical chemistry/auto analyzerElectrolyte/MetalClinical chemistry/auto analyzerSteroidClinical chemistry/auto analyzerSmall moleculeClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerProteinElectrophoresisPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Biomarker level High GOTNormal GOTBiospecimen Preservation Type of fixation/preservation None (fresh)RefrigerationStorage Storage conditions Cork stopperRubber stopperStorage Storage duration 1 day2 days3 days4 days7 daysStorage Storage temperature 24 degrees C37 degrees C4 degrees C
Purpose
The purpose of this study was to determine the effects of pH and storage temperature and duration on levels of supplemented 5-hydroxyindoleacetic acid in urine.
Summary of Findings
Hydroxyindoleacetic acid levels were stable in urine stored for 7 days at 4 or 43-51 degrees C when the pH of the urine was 3-8. Additionally, levels were stable in urine stored at 4 degrees C when the pH was 1.4, but levels decreased in urine with a pH of 1.4 after storage for more than 3 days at 56 degrees C.
Biospecimens
FluidUrinePreservation Types
None (Fresh)Other PreservativeDiagnoses
Not specifiedPlatforms
ProteinClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components pH 1.433.34566.66.77Biospecimen Preservation Type of fixation/preservation None (fresh)RefrigerationStorage Storage duration 1 day2 days3 days4 days7 daysStorage Storage temperature 4 degrees C43-51 degrees C56 degrees C
Purpose
The purpose of this study was to determine the effects of anticoagulant type, storage temperature, storage duration, and light exposure on hematology parameters in whole blood and levels of exogenous ethanol.
Summary of Findings
For disodium EDTA whole blood with initial levels in the normal range, the sedimentation rate decreased with storage, but the authors report the change was probably not significant. In specimens with a high initial sedimentation rate, the sedimentation rate decreased with storage after 1 day at room temperature in both specimens stored in the dark and 1 of 2 stored in the light, and the sedimentation rate also decreased after 2 days of storage at 4 degrees C. In a single specimen collected with oxalate, the number of red blood cells decreased by 40% after storage at room temperature for 36 h. Further, in oxalated blood, the reticulocyte count decreased after 6 h of storage at 4, 24 or 37 degrees C, with the largest decrease noted at 37 degrees C. Reticulocyte counts in the two EDTA blood specimens also decreased progressively with storage, but the rates of decrease were slower than that observed with oxalated blood. Ethanol levels in whole blood were unaffected by storage of specimens for up to 12 days at 4, 25, 37 or 56 degrees C.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Other PreservativeDiagnoses
Not specifiedPlatforms
Cell count/volumeHematology/ auto analyzerSmall moleculeGCPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Biomarker level High sedimentation rateNormal sedimentation rateBiospecimen Acquisition Anticoagulant EDTAOxalateBiospecimen Preservation Type of fixation/preservation None (fresh)RefrigerationStorage Storage conditions In the darkIn the lightStorage Storage duration 0 h12 days12 h18 h2 days24 h3 days30 h36 h4 days6 days6 h7 daysStorage Storage temperature 24 degrees C37 degrees C4 degrees C56 degrees C