Storage of thawed plasma for a liquid plasma bank: impact of temperature and methylene blue pathogen inactivation.
Thiele T, Kellner S, Hron G, Wasner C, Nauck M, Zimmermann K, Wessel A, Warkentin TE, Greinacher A, Selleng K
Purpose
The purpose of this paper was to determine the effects of storing plasma at room temperature or 4 degrees C, with or without methylene blue (MB)/light treatment, for up to 7 days on levels of 14 clotting factors.
Conclusion
Factor (F)VIII, Protein S, FV, FVII, and von Willebrand factor antigen (vWF-Ag) levels decreased during the 7 days of storage at 4 degrees C, but all other analytes were unaffected by storage at 4 degrees C. Conversely, only the levels of protein C were unaffected by storage at room temperature for 7 days, while all other analytes showed significant changes. MB/light treatment led to statistically significant, but clinically insignificant decreases in 5 analytes, larger, decreases in FVIII, Protein S, FVII, and vWF-Ag levels, and increases in FV and FX levels with storage of plasma at 4 degrees C compared to untreated plasma stored for the same length of time.
Studies (1)
Purpose
The purpose of this study was to determine the effects of effects of storing apheresis plasma at room temperature or 4 degrees C with or without MB/light treatment for up to 7 days on levels of 14 clotting factors. Plasma was stored at -20 degrees C for 14-408 days prior to thawing at 37 degrees C and experimental storage.
Summary of Findings
FVIII, Protein S, FV, FVII, and vWF-Ag levels decreased by 49% (p<0.0001), 51% (p<0.0001), 19% (p<0.0001), 15% (p=0.0439) and 11 % (p<0.0001), respectively after 7 days of storage at 4 degrees C, but all other analytes were unaffected by storage of plasma for a week at 4 degrees C. Conversely, only the levels of protein C were unaffected by storage of plasma at room temperature for 7 days. MB/light treatment led to statistically significant, but clinically insignificant decreases in FVIII (-23%, p<0.0001), FV (-17%, p<0.0001) FX1 (-13%, p<0.0001 ), FXIV (-11%, p=0.0011), and FX (-11%, p=0.003). The decreases in FVIII, Protein S, FVII, and vWF-Ag levels with storage at 4 degrees C were more pronounced in MB-light treated plasma than in untreated plasma, and FV and FX levels increased with storage of MB-light treated plasma at 4 degrees C compared to untreated, or unstored specimens.
Biospecimens
FluidPlasmaPreservation Types
FrozenDiagnoses
Not specifiedPlatforms
GlycoproteinHematology/ auto analyzerGlycoproteinColorimetric assayProteinHematology/ auto analyzerProteinColorimetric assayProteinImmunoturbidometric assayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Storage conditions Methylene blue/light treatedNot methylene blue/light treatedStorage Storage duration 0 days3 days5 days7 daysStorage Storage temperature 4 degrees CRoom temperature