Skip to main content

High-resolution copy number analysis of paraffin-embedded archival tissue using SNP BeadArrays.

Oosting J, Lips EH, van Eijk R, Eilers PH, Szuhai K, Wijmenga C, Morreau H, van Wezel T

Publication: Genome Res (2007) • Vol 17 • Page 368-76PMID: 17267813View on PubMed

Purpose

The purpose of this paper was to determine the effects of using formalin-fixed paraffin-embedded (FFPE) instead of frozen specimens on copy number determination by array comparative genomic hybridization (aCGH) and to compare the results between three array types.

Conclusion

All three platforms slightly overestimated the copy number for normal specimens, and copy numbers for regions with a gain were slightly higher while those with a loss were slightly lower when determined by GeneChip than when determined with bacterial artificial chromosome (BAC) arrays or BeadArrays. The copy number variation (CNV) was comparable between frozen and FFPE specimens using BAC and BeadArrays. The authors report the BeadArrays allowed for detection of loss of heterozygosity (LOH) by physical loss as well as copy neutral LOH.

Studies (1)

Purpose

The purpose of this study was to determine the effects of using FFPE instead of frozen colorectal tumors and normal adjacent specimens on copy number determination by aCGH and to compare the results obtained between three array types. DNA was extracted from sections of frozen specimens using the genomic Wizard kit and from 0.6 mm punches of FFPE tissue using Chelex-100 and cleaned up with the Wizard kit.

Summary of Findings

All three platforms slightly overestimated the copy number for normal specimens, and copy numbers for regions with a gain were slightly higher while those with a loss were slightly lower when determined by GeneChip rather than with BAC arrays or BeadArrays. The CNV was comparable between frozen and FFPE specimens using BAC and BeadArrays, but the correlation between frozen and FFPE specimens was 0.85 which was lower than the correlations between arrays (r=0.93-0.95) or between replicates with different intensity (r=0.92). However, exclusion of one specimen increased the correlation between FFPE and frozen specimens using BeadArrays to 0.96. The authors report the BeadArrays allowed for detection of LOH by physical loss as well as copy neutral LOH.

  • Biospecimens

    TissueColorectal
  • Preservation Types

    FrozenFormalin
  • Diagnoses

    NeoplasticCarcinoma
    NeoplasticNormal Adjacent
    NeoplasticBenign
  • Platforms

    DNAArray CGH
    DNADNA microarray
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationType of fixation/preservation
    Formalin (buffered)
    Frozen
    Array CGH SpecificType of array
    Affymetrix 10 K Xba1 2.0 array
    Custom BAC array
    Illumina Sentrix Beadarray