Skip to main content

Oligonucleotide array outperforms SNP array on formalin-fixed paraffin-embedded clinical samples.

Nasri S, Anjomshoaa A, Song S, Guilford P, McNoe L, Black M, Phillips V, Reeve A, Humar B

Publication: Cancer Genet Cytogenet (2010) • Vol 198 • Page 1-6PMID: 20303007View on PubMed

Purpose

The purpose of this paper was to determine the effects of DNA microarray platform on agreement in copy number determination between matched snap-frozen and formalin-fixed paraffin-embedded (FFPE) specimens.

Conclusion

DNA from FFPE specimens was highly degraded compared to that from snap-frozen specimens. Using the SNP array there was 53.8-87.3% agreement between FFPE and matched frozen specimens, but a more than 98% agreement was observed using the Agilent 4x44 K oligonucleotide arrays. The authors state the agreement was independent of DNA fragment size.

Studies (1)

Purpose

The purpose of this study was to determine the effects of using DNA from FFPE instead of snap-frozen colorectal specimens on DNA integrity and copy number determination using two platforms. FFPE specimens were stored for 5 years at room temperature while frozen specimens were stored at -80 degrees C for 5 years. DNA was extracted from deparaffinized FFPE specimens and snap frozen sections using QIAamp.

Summary of Findings

While high molecular weight DNA was extracted from snap-frozen specimens which allowed for amplification of Glyceraldehyde 3-phosphate dehydrogenase (GAPDH) fragments of up to 700 bp, the FFPE specimens yielded highly degraded DNA with a maximum GAPDH amplicon size of 300-400 bp. Using the SNP array, there was 53.8-87.3% agreement in copy number between FFPE and matched frozen specimens, but a more than 98% agreement was observed using the Agilent 4x44 K oligonucleotide arrays. The discrepancies using the SNP arrays were larger for the copy number variation (CNV) probes than the SNP probes, but were still significant when CNV probes were excluded from analysis. The authors state the agreement in copy number determination was independent of DNA fragment size.

  • Biospecimens

    TissueColorectal
  • Preservation Types

    FrozenFormalin
  • Diagnoses

    Normal
  • Platforms

    DNADNA microarray
    DNACGH
    DNAElectrophoresis
    DNAPCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationType of fixation/preservation
    Formalin (buffered)
    Snap frozen
    PCR SpecificLength of gene fragment
    100 bp
    200 bp
    300 bp
    400 bp
    500 bp
    600 bp
    700 bp
    PCR SpecificTargeted nucleic acid
    GAPDH
    DNA microarray SpecificType of array
    Affymetrix (SNP) 6.0
    Agilent 4x44 K oligonucleotide arrays