No evidence for interference of h&e staining in DNA testing: usefulness of DNA extraction from h&e-stained archival tissue sections.
Morikawa T, Shima K, Kuchiba A, Yamauchi M, Tanaka N, Imamura Y, Liao X, Qian ZR, Brahmandam M, Longtine JA, Lindeman NI, Fuchs CS, Ogino S
Purpose
The purpose of this paper was to determine the effects of histological staining of formalin-fixed paraffin-embedded (FFPE) tissue sections on DNA integrity and analysis of DNA by real-time PCR, microsatellite analysis and pyrosequencing.
Conclusion
Histological staining of FFPE tissue sections did not impact DNA integrity as determined by electrophoresis, real-time PCR GAPDH cycle threshold (CT) values, microsatellite mean peak height, and sequencing quality or results.
Studies (1)
Purpose
The purpose of this study was to determine the effects of histological staining of FFPE tissue sections on DNA integrity and analysis of DNA by real-time PCR, microsatellite analysis and pyrosequencing. Non-coverslipped whole sections of FFPE tissue were either unstained , hematoxylin stained for 3 min, eosin stained for 15 sec, or hematoxylin and eosin stained. Tissue was scraped into tubes, and DNA was extracted with QIAamp.
Summary of Findings
Histological staining of FFPE tissue sections did not impact DNA integrity as determined by electrophoresis, real-time PCR GAPDH CT values, microsatellite mean peak height, and sequencing quality or results.
Biospecimens
TissueColorectalPreservation Types
FormalinDiagnoses
NeoplasticCarcinomaNot specifiedPlatforms
DNAElectrophoresisDNADNA sequencingDNAMicrosatellite analysisDNAReal-time qPCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Real-time qPCR Specific Targeted nucleic acid GAPDHReal-time qPCR Specific Type of tissue stain EosinH&EHematoxylinUnstainedElectrophoresis Specific Type of tissue stain EosinH&EHematoxylinUnstainedDNA sequencing Specific Type of tissue stain EosinH&EHematoxylinUnstained