Paraffin-embedded tissue is less accurate than frozen section analysis for determining VHL mutational status in sporadic renal cell carcinoma.

Verhoest G, Patard JJ, Fergelot P, Jouan F, Zerrouki S, Dreano S, Mottier S, Rioux-Leclercq N, Denis MG

Publication: Urol Oncol (2012) • Vol 30 • Page 469-75PMID: 20863722View on PubMed

Purpose

The purpose of this paper was to compare Von Hippel-Lindau tumor suppressor (VHL) gene mutation status in formalin-fixed paraffin-embedded (FFPE) and frozen sporadic renal cell carcinoma specimens and to determine the effects of block characteristics and formalin fixation duration.

Conclusion

The VHL gene mutation rate using DNA from frozen specimens was 98%, but the mutation rate using DNA from matched FFPE specimens was only 52% and only 40.8% of mutations identified in FFPE specimens were concordant with those identified in the matched frozen specimen. Approximately two thirds of the discordance in sequencing results was due to the identification of a mutation in the frozen specimen but not in the FFPE specimen. Increased DNA quality significantly increased sequencing success and decreased discordance with frozen specimens, but DNA concentration, presence of more than 70% tumor, block imperfections, fixation for more than 24 h, and tumor grade did not affect sequencing success or concordance with frozen specimens.

Studies (1)

Purpose

The purpose of this study was to compare VHL gene mutational status in FFPE and frozen sporadic renal cell carcinoma specimens and to determine the effects of block characteristics and formalin fixation duration. DNA was extracted from 8 10 um, xylene-deparaffinized, proteinase K-digested sections using RecoverAll. Exons 1 and 3 of VHL are GC rich and required the addition of 3% DMSO for PCR amplification. The authors report about half of the FFPE blocks had evidence of necrosis, fat, edema, fibrosis, or hemorrhagic or cystic zones.

Summary of Findings

Sequencing was not possible from 21/76 FFPE blocks of which 15 had DNA classified as highly degraded by electrophoresis. Interestingly, the mutation rate of frozen specimens was 98%, but the mutation rate of FFPE specimens was 52%. Only 40.8% of the mutations identified in FFPE specimens were concordant with those identified in the matched frozen specimen. When only specimens with slightly degraded DNA were considered, sequencing was possible in 44/50 cases, of which 30 had concordant results with frozen specimens. All 11 cases where specimens had highly degraded DNA that was still able to be sequenced yielded discordant sequencing results. Approximately two thirds of the discordance in sequencing results was due to a mutation identified in the frozen specimen but not in the FFPE specimen. Increased DNA quality significantly increased sequencing success and decreased discordance (p=0.0001, both), but DNA concentration, presence of more than 70% tumor, block imperfections, fixation for more than 24 h, and tumor grade did not significantly affect sequencing success, sequence concordance or DNA quality. The authors confirmed sequencing results for frozen specimens using a repeat block, but repeat FFPE blocks did not have concordant sequence.

  • Biospecimens

    TissueKidney
  • Preservation Types

    FormalinFrozen
  • Diagnoses

    NeoplasticCarcinoma
  • Platforms

    DNADNA sequencing
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationTime in fixative
    24 h
    48 h
    72 h
    96 h
    Biospecimen PreservationType of fixation/preservation
    Formalin (buffered)
    Frozen
    DNA sequencing SpecificTargeted nucleic acid
    VHL exon 1
    VHL exon 2
    VHL exon 3