Skip to main content

Critical steps in tissue processing in histopathology.

Comanescu M, Annaratone L, D'Armento G, Cardos G, Sapino A, Bussolati G

Publication: Recent Pat DNA Gene Seq (2012) • Vol 6 • Page 22-32PMID: 22208680View on PubMed

Purpose

The purpose of this paper was to determine the effects of cold ischemia time on RNA integrity number (RIN) values in unfixed specimens and to determine the effects of formalin fixation temperature on mRNA expression by whole genome array analysis and real time qRT-PCR with a comparison to frozen specimens.

Conclusion

RIN values remained acceptable (all >7), regardless of cold ischemia time (1-72 h) when unfixed specimens were sealed in plastic bags under-vacuum and cooled to 4 degrees C immediately after procurement. Cycle threshold (Ct) values were slightly higher for formalin-fixed paraffin-embedded (FFPE) tissue fixed at room temperature than for FFPE tissue fixed at 4 degrees C, but frozen tissue gave the lowest Ct values. No significant differences were noted in the normalized gene expression levels between differently preserved specimens. Whole genome array analysis revealed that a similar number of transcripts were detected in RNA extracted from FFPE tissue fixed at 4 degrees C and from frozen tissue, but the lists were not entirely overlapping. Formalin fixation at 4 degrees C allowed for the amplification of RNA fragments up to 660 bp long, which the authors report was an improvement over room temperature-fixed FFPE specimens. The authors also report that microarray gene expression analysis was similar between cold fixed FFPE and frozen specimens.

Studies (3)

Purpose

The purpose of this study was to determine the effects of cold ischemia time at 4 degrees C for specimens that were sealed in plastic bags under-vacuum and cooled immediately after procurement on RIN values.

Summary of Findings

RIN values remained acceptable (all >7), regardless of cold ischemia time for specimens that were sealed in plastic bags under-vacuum and cooled to 4 degrees C immediately after procurement. The average RIN values after cold ischemia times of 1-4 h, 5 h, 6-23 h, 24-48 h, and 60-72 h were 8.2, 7.8, 8.0, 7.8, and 7.5, respectively.
  • Biospecimens

    TissueBreast
  • Preservation Types

    None (Fresh)
  • Diagnoses

    NeoplasticCarcinoma
  • Platforms

    RNAAutomated electrophoresis/Bioanalyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionCold ischemia time
    1-4 h
    24-48 h
    5 h
    6-23 h
    60-72 h