Skip to main content

Placental tissue as model for pilot study focused on RNA analysis from human foetal tissue.

Hulkova, Zeman J

Publication: Prague Med Rep (2011) • Vol 112 • Page 93-101PMID: 21699758View on PubMed

Purpose

The aims of this paper were to determine if a 1 or 2 h delay at 0 or 24 degrees C prior to snap freezing affects the yield or integrity of RNA, and to identify promising reference genes for semi-quantitative RT-PCR analysis of placental tissue.

Conclusion

Control placenta specimens snap frozen in liquid nitrogen immediately after a wash in physiological buffer displayed low RNA integrity numbers, ranging from 3.0 to 7.2. Although case-matched specimens were not compared to 0 h controls, the authors report a nonsignificant decline in RIN and the MECP2 transcript after 2 h of cold ischemia compared to 1 h, and after storage at 24 degrees C compared to 0 degrees C. While the authors report significant positive correlations between RNA yield and specimen weight, and RNA yield and purity, it is unclear whether specimen size was a controlled variable. Although data was not shown, the authors report that poor RNA quality was associated with a low infant Apgar score, while RNA yield remained unaffected.

Studies (1)

Purpose

The aims of this study were to determine if a 1 or 2 h delay at 0 or 24 degrees C prior to snap freezing affects the yield or integrity of RNA, and to identify promising reference genes for semi-quantitative RT-PCR analysis of placental tissue. Placenta specimens were collected from 20 healthy individuals following the birth of infants with Apgar scores ranging from 3 to 7. Placenta specimens were rinsed in physiological buffer prior to immediate snap freezing in liquid nitrogen or a 1-2 h delay at 0 or 24 degrees C.

Summary of Findings

For placenta specimens snap frozen immediately, RNA purity (determined by OD 260/280 ratio) was negatively correlated to RNA yield (r= -0.61, p<0.01), and although it is unclear whether specimen size was a controlled variable the authors report a positive correlation between RNA yield and sample weight (r=0.46, p<0.05). Placenta specimens subjected to 1 or 2 h of cold ischemia at 0 degrees C displayed a similar negatively correlation between RNA yield and purity (r= -0.94 and r= -0.83, respectively; p<0.05). Although data was not shown, the authors note that poor RNA quality was associated with a low Apgar score, while RNA yield remained unaffected. RIN was also adversely, although not significantly, affected by the longer ischemia times and the higher temperature, with lower RINs observed after 2 h compared to 1 h at 0 degrees C (5.0 versus 5.4, respectively), and at 24 degrees (3.5 versus 4.4, respectively). The abundance, but not rate of success, of a 378 bp RT-PCR amplicon was influenced by the duration and temperature of cold ischemia. Specimens subjected to 1 h of cold ischemia at 0 degrees C generated the most abundant amplicon, although the temperature of cold ischemia produced more robust differences in amplicon intensity than the duration.
  • Biospecimens

    TissuePlacenta
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
  • Platforms

    RNAAutomated electrophoresis/Bioanalyzer
    RNAElectrophoresis
    RNART-PCR
    RNASpectrophotometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    High Apgar score (8-10)
    Low Apgar score (3-7)
    Biospecimen AcquisitionCold ischemia time
    0 h
    1 h
    2 h
    StorageStorage temperature
    0 degrees C
    24 degrees C
    RT-PCR SpecificTargeted nucleic acid
    MECP2