Stability of serum thyroid hormones following 8-11 years of cold storage.
Panesar NS, Lit LC
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of 8-11 years of frozen storage and type of assay used for measuring TSH, FT4 and FT3 in serum from pregnant women. The ACS180 assay was used only for fresh specimens, and a subset of specimens were assayed fresh using the E170 assay. Frozen specimens were stored at -80 degrees C for 8-11 years or were newly archived at -80 degrees C (unspecified duration).
Summary of Findings
Serum FT4 levels were 17.6% higher in specimens stored frozen for 8-11 years and measured using the E170 than when measured using ACS180 in the same specimens prior to freezing, but only an 11% difference was found when fresh specimens were measured using ACS180 and E170. In specimens stored for 8-11 years, FT3 levels measured using the E170 were 42% higher than when measured in the same specimens prior to freezing with the ACS180, but when fresh specimens were measured with the E170, FT3 levels were 10% lower than when measured with the ACS180. In specimens stored frozen 8-11 years, TSH levels were slightly lower using all three assays than when measured in the same specimens prior to freezing using the ACS180. TSH results showed significant correlations between the 4 assays in specimens stored 8-11 years, newly archived specimens and fresh specimens (r2>0.96 for all). FT4 levels had correlation coefficients of 0.8-0.93 between measurements with the different assays in fresh and newly archived specimens. FT3 levels had correlation coefficients between methods of 0.59-0.89 in fresh and newly archived specimens.
Biospecimens
FluidSerumPreservation Types
None (Fresh)FrozenDiagnoses
PregnantPlatforms
GlycoproteinClinical chemistry/auto analyzerPeptideClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition Pregnant (5-41 weeks)Biospecimen Preservation Type of fixation/preservation FrozenNone (fresh)Storage Storage duration 0 days0 years8-11 yearsClinical chemistry/auto analyzer Specific Technology platform ACS180ArchitectCentaurE170