Skip to main content

Investigation of the stability of selenoproteins during storage of human serum by size-exclusion LC-ICP-MS.

Palacios O, Lobinski R

Publication: Talanta (2007) • Vol 71 • Page 1813-6PMID: 19071527View on PubMed

Purpose

The purpose of this paper was to determine the effects of post-thaw storage temperature and duration on selenoprotein levels in serum by liquid chromatography inductively coupled plasma mass spectrometry (LC-ICP-MS).

Conclusion

With increasing post-thaw storage at 4 degrees C or room temperature, the peak associated with the selenoalbumin and glutathione peroxidase (GSHPx) tetramer decreased, and the peak associated with selenite (Se(IV)) increased. The changes were faster when the specimens were stored at room temperature than when stored at 4 degrees C. When post-thaw storage was at 4 degrees C, but not room temperature, the peak associated with selenoprotein P (sel P) decreased, and the peak associated with the GSHPx monomer increased with increasing storage duration.

Studies (1)

Purpose

The purpose of this study was to determine the effects of post-thaw storage temperature and duration on selenoprotein levels in serum by LC-ICP-MS. The authors provide no details on the collection or storage of serum prior to thawing.

Summary of Findings

With increasing post-thaw storage at 4 degrees C or room temperature, the peak associated with the selenoalbumin and GSHPx tetramer decreased, and the peak associated with Se(IV) increased. The changes were faster when the specimens were stored at room temperature than when stored at 4 degrees C. When post-thaw storage was at 4 degrees C, but not room temperature, the peak associated with sel P decreased, and the peak associated with the GSHPx monomer increased with increasing storage duration. The authors report that a year of -20 degrees storage of serum did not lead to any changes in selenoprotein-associated peak heights. Post-thaw storage at 4 degrees C or room temperature did not affect levels of selenate (Se(VI)) or selenomethionine (Sel-Met) in serum. Addition of hydrogen peroxide (H2O2) to thawed serum specimens led to a decrease in the GSHPx peak and an increase in the Se(IV) peak without affecting the sel P peak.
  • Biospecimens

    FluidSerum
  • Preservation Types

    Frozen
  • Diagnoses

    Not specified
  • Platforms

    ProteinLC-MS or LC-MS/MS
    Small moleculeLC-MS or LC-MS/MS
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StoragePost-thaw duration
    0 days
    1 month
    15 days
    4 months
    StorageStorage conditions
    No additive
    With 0.15% H2O2
    StorageThaw temperature/condition
    4 degrees C
    Room temperature