THE EFFECT OF VENOUS OCCLUSION ON DETERMINATION OF PROTEIN-BOUND IODINE.
LEWITUS Z, STEINITZ K
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of venous stasis on PBI and total protein levels in blood. The first specimen was collected with no venous stasis from one arm, and then the second was collected from the opposite arm after 5 min of 100 mM mercury (Hg) pressure from a blood pressure cuff.
Summary of Findings
Significantly higher total protein (average 22%) and PBI levels (average 22.4%) were measured in the specimens obtained after 5 min of venous stasis compared to those obtained with no venous stasis. The authors state that there was a correlation between the change in PBI levels and the change in total protein levels.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
Other diagnosesPlatforms
ProteinColorimetric assayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition Diffuse goiterEuthyroidHyperthyroidismMitral stenosisNeurovegetative insufficiencyThyroidectomyThyrotoxicosisBiospecimen Acquisition Method of fluid acquisition Tourniquet times compared