Effect of platelet-associated virus on assays of HIV-1 in plasma.
Lee TH, Stromberg RR, Henrard D, Busch MP
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of plasma and platelet preparation methods on HIV-1 viral load quantification. Specimens were collected from 2 HIV-1 seropositive patients. The authors do not specify what type of anticoagulant or collection tubes were used or whether fresh or frozen blood specimens were used.
Summary of Findings
A higher concentration of HIV-1 RNA was found in purified platelets prepared by centrifugation of whole blood for 5 min at 250 x g, leukodepletion, and pelleting of platelets at 10,000 x g for 15 min plus washing of the pellet than in platelet free plasma prepared by centrifugation of whole blood at 200 x g for 15 min, 1000 x g for 15 min, and lastly 10,000 x g for 15 min. Platelet pellets from this last centrifugation step harbored a significant amount of HIV-1 RNA.
Biospecimens
FluidPlasmaFluidBloodPreservation Types
None (Fresh)Diagnoses
AIDS/HIV-relatedPlatforms
RNAReal-time qRT-PCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Blood and blood products PlasmaPlatelet-poor plasmaPlatelet-rich plasmaPlateletsBiospecimen Aliquots and Components Centrifugation Different number of centrifugation steps comparedMultiple durations comparedMultiple speeds compared