Skip to main content

Longitudinal stability of coagulation, fibrinolysis, and inflammation factors in stored plasma samples.

Lewis MR, Callas PW, Jenny NS, Tracy RP

Publication: Thromb Haemost (2001) • Vol 86 • Page 1495-500PMID: 11776319View on PubMed

Purpose

The purpose of this paper was to determine the effects of storage at -70 degrees C on the levels of coagulation, fibrinolysis, and inflammation factors in plasma.

Conclusion

Due to some analytes increasing over time in some plasma pools while they decreased in others, no overall effects of storage were observed in mean levels of analytes, but levels of some individual analytes changed in one or two frozen or lyophilized plasma pools during storage. There was no significant effect of using lyophilized rather than frozen pools.

Studies (1)

Purpose

The purpose of this study was to determine the effects of frozen storage at -70 degrees C on the levels of coagulation, fibrinolysis, and inflammation factors in frozen and lyophilized plasma pools. Frozen and lyophilized plasma pools were purchased from commercial vendors, and other plasma pools were produced in the laboratory. Experimental storage was considered to begin after first use in the laboratory.

Summary of Findings

The mean coefficient of variance (CV) of the average monthly levels of the analytes ranged from 2.6% (fibrinogen)-11.1% (D-dimer). Effects of storage were observed in some individual frozen and lyophilized plasma pools. With increasing storage at -70 degrees C, 1 of 4 and 2 of 2 frozen plasma pools showed increasing CRP and PAI-1 levels, respectively, and 1 of 4 and 1 of 2 frozen plasma pools showed decreasing levels of CRP and Protein S, respectively. With increasing storage at -70 degrees C, 1 of 5, 1 of 2 and 1 of 1 lyophilized plasma pools showed increasing fibrinogen, PAI-I antigen and protein S levels, respectively, and 1 of 5 lyophilized plasma pools showed decreasing levels of fibrinogen. There was no significant effect of using lyophilized rather than frozen pools. Repeated measures analysis identified a significant storage by time effect on fibrinogen levels (p=0.013), but the authors report no trends were observed when the 4 month average levels were compared.

  • Biospecimens

    FluidPlasma
  • Preservation Types

    FrozenOther Preservative
  • Diagnoses

    Not specified
  • Platforms

    ProteinELISA
    ProteinClinical chemistry/auto analyzer
    ProteinHematology/ auto analyzer
    GlycoproteinHematology/ auto analyzer
    PeptideELISA
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationType of fixation/preservation
    Frozen
    Lyophilized
    StorageStorage duration
    7-59 months