Diurnal variations of interleukin-6 plasma levels are confounded by blood drawing procedures.
Haack M, Kraus T, Schuld A, Dalal M, Koethe D, Pollmächer T
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of collection time, method of blood draw, and sleep deprivation on IL-6 and cortisol levels in plasma. Specimens were obtained every half hour for 24 h by IV catheter. In addition, a needle collection was performed on the opposite arm, in parallel to the IV catheter collection, at the last time point. Plasma was frozen at -20 degrees C until assayed.
Summary of Findings
Throughout the 24 hour time course experiment, IL-6 levels showed both a linear increase (p<0.01) and a quadratic component (p<0.001). Average IL-6 levels were significantly higher when volunteers followed a normal sleep pattern (sleeping from 11:00 pm to 7:00 am with lights off) rather than when they were kept awake for 24 h (p=0.08). Specimens obtained by needle stick at 10:00 am on day 2 of the experiment did not differ significantly from specimens obtained through IV catheter at 10:00 am on day 1 of the experiment, but specimens obtained by IV catheter at 10:00 am on day 2 were an average of 225% higher than those obtained by the same method 24 h earlier, and consequently, they were also significantly higher than the needle stick specimens (both p<0.01). Difficult blood collections (rated by the technician) resulted in significantly higher IL-6 levels (p<0.001) and were more frequently encountered in patients with a normal sleep period as opposed to the sleep deprivation period. Cortisol levels tended to peak in the early morning, were unaffected by sleep deprivation, and were not associated with IL-6 levels.
Biospecimens
FluidPlasmaFluidBloodPreservation Types
FrozenDiagnoses
NormalPlatforms
SteroidRadioimmunoassayProteinELISAPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition Normal sleep scheduleSleep deprivation scheduleBiospecimen Acquisition Method of fluid acquisition Difficult blood drawIV catheterNeedleNot a difficult blood drawBiospecimen Acquisition Time of biospecimen collection Every half hour between 10:00 am day 1 and 10:00 am day 2