The impact of the intensity of serial automated plasmapheresis and the speed of deep-freezing on the quality of plasma.

Hellstern P, Bach J, Haubelt H, Hitzler WE, Mathis S, Vogt A

Publication: Transfusion (2001) • Vol 41 • Page 1601-5PMID: 11778078View on PubMed

Purpose

The purpose of this paper was to determine the effects of plasma donation frequency and freezing rate on levels of hematological analytes in plasma.

Conclusion

Plasma from frequent donors (median every 5 days) frozen slowly at -30 degrees C had lower concentrations of total protein, albumin, immunoglobulin G (IgG), fibrinogen, factor V, factor VIIC, and prothrombin fragments 1+2 (F1+2) than plasma collected from moderate donors (median every 14 days) that was frozen rapidly at -80 degrees C. While the plasma was collected and diluted using the same ratios and equipment, the plasma from frequent donors frozen slowly had higher concentrations of citrate than plasma collected from moderate donors frozen rapidly at -80 degrees C, indicating less dilution of the specimens and that the volume of plasma was greater from frequent donors.

Studies (1)

Purpose

The purpose of this study was to determine the effects of plasma donation frequency and freezing rate on the collected volume and levels of 15 hematological analytes in plasma. Citrated plasma was either collected in the United States where it was frozen slowly in a -30 degree walk-in freezer or in Germany where it was rapidly frozen at -80 degrees C (reached -30 degrees C in < 1 h). Plasma was shipped frozen at -25 degrees C, stored frozen at -30 degrees C, thawed in the plastic bags at 37 degrees C, aliquoted, and stored frozen at -70 degrees C until analysis.

Summary of Findings

Plasma from frequent donors (median every 5 days) frozen slowly at -30 degrees C had a higher average volume (p<0.0001) and lower concentrations of total protein (p<0.0001), albumin (p<0.007) and IgG (p<0.0001) than plasma collected from moderate donors (median every 14 days) that was frozen rapidly at -80 degrees C. Further, while the plasma was collected and diluted using the same ratios and equipment, the plasma from frequent donors frozen slowly had higher concentrations of citrate (p<0.0001) than plasma collected from moderate donors frozen rapidly at -80 degrees C, indicating less dilution of the specimens. Plasma from frequent donors frozen slowly at -30 degrees C had lower concentrations fibrinogen (p<0.006), factor V (p<0.0001), factor VIIC (p=0.04 by chromogenic assay, p<0.0001 by one-stage clotting assay), and F1+2 (p=0.002) than plasma collected from moderate donors frozen rapidly at -80 degrees C. Further, levels of factor VIIC (p=0.005 both assays), and F1+2 (p=0.001) were higher in aliquots of plasma frozen at -80 degrees C than in aliquots from the same specimens frozen at -30 degrees C, and the ratio of factor VIIC by the two assays was significantly different. Donation frequency and freezing rate did not affect prothrombin time, factor VII, von Willebrand factor, factor IX, antithrombin time, Protein C, or D-dimer levels.

  • Biospecimens

    FluidPlasma
    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
  • Platforms

    ProteinColorimetric assay
    ProteinHematology/ auto analyzer
    Small moleculeClinical chemistry/auto analyzer
    GlycoproteinColorimetric assay
    GlycoproteinHematology/ auto analyzer
    PeptideImmunoassay
    PeptideHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Frequent plasma donor (median every 5 days)
    Moderate plasma donor (median every 14 days)
    Biospecimen PreservationCooling or freezing method/ rate
    At -30 degrees C
    At -80 degrees C
    Hematology/ auto analyzer SpecificTechnology platform
    Chromogenic assay