Effect of long-term storage at -80 degrees C on the various lipid parameters in stored plasma samples.
Devanapalli B, Bermingham MA, Mahajan D
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of storage at -80 degrees C on the lipid profile of EDTA-plasma from fasting volunteers. The same machines and operator were used for the two analysis performed 1 year apart.
Summary of Findings
After storage for 1 year at -80 degrees C, TC declined by an average of 21% (p<0.0001), and Tg declined by an average of 42% (p<0.0001), with a larger decline in Tg found in specimens with initial concentrationsin fresh specimens of >2 mmol/L. In general, HDL-C was unaffected by storage at -80 degrees C, however, specimens with an initial HDL-C concentration of <1 mmol/L showed an increase with storage. When initial levels of Lp(a) were <300 mg/dL, there was a slight increase with storage at -80 degrees C (p<0.0001), and when initial levels were >300 mg/dL, there was a large decline in Lp(a) concentration with storage (>75%, p=0.0002).
Biospecimens
FluidPlasmaPreservation Types
FrozenNone (Fresh)Diagnoses
Not specifiedPlatforms
LipidClinical chemistry/auto analyzerLipoproteinClinical chemistry/auto analyzerSteroidClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Biomarker level <1 mmol/L HDL-C<2 mmol/L Tg<300 mg/dL Lp(a)<55 mmol/L total cholesterol>1 mmol/L HDL-C>2 mmol/L Tg>300 mg/dL Lp(a)>55 mmol/L total cholesterolBiospecimen Preservation Type of fixation/preservation FrozenNone (fresh)Storage Storage duration 1 year<2 h