Skip to main content

Effect of tourniquet pressure and intra-individual variability on plasma fibrinogen, platelet P-selectin and monocyte tissue factor.

Ritchie JL, Crawford VL, McNulty M, Alexander HD, Stout RW

Publication: Clin Lab Haematol (2000) • Vol 22 • Page 369-72PMID: 11318805View on PubMed

Purpose

The purpose of this paper was to determine the effects of tourniquet use during blood collection on plasma fibrinogen, platelet P-selectin, and monocyte tissue factor levels.

Conclusion

P-selectin, tissue factor, and fibrinogen levels were not significantly between specimens collected at 1 week intervals from the same 4 individuals. Application of tourniquet pressure during the entire blood collection process (right arm, no blood discarded) versus only until just after the butterfly needle was inserted (left arm, 2 mL discarded) did not affect P-selectin, tissue factor, or fibrinogen levels.

Studies (1)

Purpose

The purpose of this study was to determine the effects of tourniquet use during blood collection on plasma fibrinogen, platelet P-selectin, and monocyte tissue factor levels. Blood was collected from the right arm while tourniquet pressure was applied, and blood was collected from the left arm with tourniquet pressure only applied long enough to inflate the vein and then released once a butterfly needle had been inserted. In the case of the left arm collection, the first 3 mL aliquot of blood was discarded and the next 9 mL was kept, but in the case of right arm collection, the initial 9 mL of blood was collected. Fresh whole blood was assayed for P-selectin and tissue factor while fibrinogen was measured in plasma that had been frozen and stored at -70 degrees C.

Summary of Findings

P-selectin, tissue factor, and fibrinogen levels were not significantly between specimens collected at 1 week intervals from the same 4 individuals. Application of tourniquet pressure during the entire blood collection process (right arm, no blood discarded) versus only until just after the butterfly needle was inserted (left arm, 2 mL discarded) did not affect P-selectin, tissue factor, or fibrinogen levels.

  • Biospecimens

    FluidPlasma
    FluidBlood
  • Preservation Types

    None (Fresh)Frozen
  • Diagnoses

    Normal
  • Platforms

    GlycoproteinClinical chemistry/auto analyzer
    ProteinFlow cytometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnatomical location of blood draw
    Arm
    Left and right sides compared
    Biospecimen AcquisitionMethod of fluid acquisition
    Tourniquet times compared
    Biospecimen AcquisitionTime of biospecimen collection
    Week 1
    Week 2
    Week 3
    Biospecimen Aliquots and ComponentsAliquot sequential collection
    1st collection
    2nd collection