A new study of intraosseous blood for laboratory analysis.
Miller LJ, Philbeck TE, Montez D, Spadaccini CJ
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of using IO verses peripheral venous blood for CBC analysis and the measurement of 10 common clinical chemistry analytes. Specimens from 9 volunteers were included in the analysis. Specimens intended for clinical chemistry analysis were centrifuged, and serum was transferred to new tubes. Hematology specimens were transferred to potassium EDTA tubes. All specimens were kept at ambient temperatures while transported to the laboratory where analysis took place within 1-6 hours of blood collection.
Summary of Findings
There were significant correlations between values obtained from IO blood and peripheral venous blood for red blood cell counts, hemoglobin, hematocrit, glucose, blood urea nitrogen, creatinine, chloride, total protein, and albumin. However, no correlations between values obtained from the two types of specimens were seen for white blood cell or platelet counts, sodium, potassium, carbon dioxide, or calcium concentrations. IO sodium, calcium, creatinine, potassium, and carbon dioxide values were within 5, 10, 25, 25, and 25% of average peripheral venous values, respectively. The first and second 4 mL aliquots of IO blood, taken after discarding 2 mL or 6 mL, respectively, had significantly correlated values for red blood cell counts, hemoglobin, hematocrit, glucose, blood urea nitrogen, creatinine, chloride, total protein, carbon dioxide, and albumin. However, white blood cell and platelet counts, sodium, potassium, and calcium concentrations were not significantly correlated between the first and 2nd aliquots of IO blood.
Biospecimens
FluidBloodFluidSerumPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
Cell count/volumeHematology/ auto analyzerProteinHematology/ auto analyzerCarbohydrateClinical chemistry/auto analyzerSmall moleculeClinical chemistry/auto analyzerElectrolyte/MetalClinical chemistry/auto analyzerGasClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anatomical location of blood draw Intraosseous collectionPeripheral veinBiospecimen Aliquots and Components Aliquot sequential collection 1st collection2nd collectionBiospecimen Aliquots and Components Aliquot size/volume 10-12 mL (venipuncture)4 mL (IO)