Skip to main content

Components of biological, including seasonal, variation in hematological measurements and plasma fibrinogen concentrations in normal humans.

Maes M, Scharpé S, Cooreman W, Wauters A, Neels H, Verkerk R, De Meyer F, D'Hondt P, Peeters D, Cosyns P

Publication: Experientia (1995) • Vol 51 • Page 141-9PMID: 7875254View on PubMed

Purpose

The purpose of this paper was to determine the effects of month of collection on measurement of hematological parameters and plasma fibrinogen concentrations.

Conclusion

All hematological analytes in this study, except for hematocrit and platelet distribution width (PDW) were found to show seasonal and or cross-seasonal differences, and hematocrit showed significant monthly differences. The differences between peak and trough analyte values throughout the year were less than 8.5% in most cases, however, platelet counts and plasma fibrinogen showed higher variability throughout the year (14.4% and 28%, respectively). Importantly, mean corpuscular hemoglobin concentration (MCHC) was the only analyte that showed higher intraindividual variability than interindividual variability.

Studies (1)

Purpose

The purpose of this study was to determine the effects of month of collection on measurement of hematological parameters and plasma fibrinogen concentrations. Healthy volunteers participating in this study in Belgium had extensive mental and physical health background checks and stringent guidelines for travel, stress, and use of any medication during the study.

Summary of Findings

Red blood cell counts (RBC), hemoglobin, mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), MCHC, red blood cell distribution width (RDW), platelet counts, mean platelet volume (MPV), plateletcrit (PCT), and fibrinogen were found to show seasonal and or cross-seasonal differences. Hematocrit showed significant monthly differences, but PDW did not show seasonal or monthly differences. There were no interactions between gender, age, and season of specimen collection for any analyte. The differences between peak and trough analyte values throughout the year were less than 8.5% in most cases, however, platelet counts and plasma fibrinogen showed higher variability throughout the year (14.4% and 28%, respectively). Importantly, MCHC was the only analyte that showed higher intraindividual variability than interindividual variability.

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    Cell count/volumeHematology/ auto analyzer
    ProteinHematology/ auto analyzer
    GlycoproteinClinical chemistry/auto analyzer
    ProteinSpectrophotometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionPatient age
    35-69 years
    <35 years
    PreaquisitionPatient gender
    Female
    Male
    Biospecimen AcquisitionTime of biospecimen collection
    April
    August
    December
    February
    January
    July
    June
    March
    May
    November
    October
    September