Skip to main content

Diurnal, seasonal, and blood-processing patterns in levels of circulating fibrinogen, fibrin D-dimer, C-reactive protein, tissue plasminogen activator, and von Willebrand factor in a 45-year-old population.

Rudnicka AR, Rumley A, Lowe GD, Strachan DP

Publication: Circulation (2007) • Vol 115 • Page 996-1003PMID: 17296859View on PubMed

Purpose

The purpose of this paper was to determine the effects of time of day and month of blood collection, patient gender, transport time, and needle type on markers of coronary artery disease.

Conclusion

Fibrinogen and D-dimer levels were higher, and tissue plasminogen activator antigen (t-PA) and von Willebrand factor (vWF) levels were lower in women than in men. Levels of each coronary artery disease marker showed unique patterns based on time of biospecimen collection (hour of the day and month of the year). The levels of D-dimer, CRP, t-PA, and vWF and the rate of hemolysis were significantly affected by delays in processing due to transport, but fibrinogen levels were not affected. Using a winged needle for blood collection decreased the incidence of hemolysis but did not affect levels of the other analytes.

Studies (1)

Purpose

The purpose of this study was to determine the effects of time of day and month of blood collection, patient gender, transport time, and needle type on markers of coronary artery disease. Citrated blood from non-fasting volunteers was transported to the laboratory at ambient temperatures (collections throughout United Kingdom), centrifuged, and plasma was stored frozen at -70 degrees C until analysis.

Summary of Findings

Fibrinogen and D-dimer levels were higher, and t-PA and vWF levels were lower in women than in men. Time of collection significantly affected levels of fibrinogen (p=0.03), CRP (p=0.003), t-PA (p<0.0001) and vWF (p<0.0001), but not D-dimer. t-PA decreased throughout the day, vWF and fibrinogen peaked at noon, CRP was highest at 3 PM and 10 PM and D-dimer levels peaked at 2 PM. Month of collection significantly affected fibrinogen (p=0.02), D-dimer (p<0.001), t-PA (p=0.0004) and vWF (p=0.003), but not CRP levels (p=0.82). D-dimer peaked between February and March (p<0.001), t-PA peaked in November (p=0.0004), vWF peaked in May (p=0.003), and fibrinogen and CRP levels were highest during winter months (p=0.02 and p=0.82, respectively). Levels of D-dimer (p=0.04), CRP (p=0.03), t-PA (p<0.0001), and vWF (p=0.0005) and the rate of hemolysis were significantly affected by delays in processing due to transport, but fibrinogen levels were not affected. Using a winged needle for blood collection decreased the incidence of hemolysis (p=0.025) but did not affect levels of the other analytes.

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    Frozen
  • Diagnoses

    Not specified
  • Platforms

    GlycoproteinHematology/ auto analyzer
    PeptideELISA
    ProteinELISA
    ProteinClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionPatient gender
    Female
    Male
    Biospecimen AcquisitionMethod of fluid acquisition
    Butterfly device
    Needle
    Biospecimen AcquisitionTime of biospecimen collection
    1 PM
    10 AM
    10 PM
    11 AM
    12 PM
    2 PM
    3 PM
    4 PM
    5 PM
    6 PM
    7 PM
    8 PM
    9 AM
    9 PM
    April
    August
    December
    February
    January
    July
    June
    March
    May
    November
    October
    September
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    StorageBetween site transportation method
    Unspecified transport method
    StorageSpecimen transport duration/condition
    2 days
    3 days
    4 days or more
    <1 day