Influence of the centrifuge time of primary plasma tubes on routine coagulation testing.
Lippi G, Salvagno GL, Montagnana M, Manzato F, Guidi GC
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of sequential collection and centrifugation duration on the measurement of coagulation and hematological analytes. Five blood specimens were collected from 10 fasting volunteers in trisodium citrate tubes after a single venipuncture. Sequentially collected aliquots were centrifuged at room temperature at 1,200 x g for increasing durations (1, 2, 5, 10 or 15 min) such that the 5th aliquot was always centrifuged for 15 min, while the first aliquot was centrifuged for just 1 min.
Summary of Findings
Compared to specimens centrifuged for the recommended 15 min, specimens centrifuged for 10 min or less had increased platelet counts (p<0.01), and those centrifuged for 5 min or less had increased red blood cell counts (p<0.05). In addition to these changes, centrifugation times of 2 min or less led to increased APTT and fibrinogen levels compared to those centrifuged for 15 min. Further, in addition to the above changes, a centrifugation time of 1 min resulted in increased white blood cell counts (p<0.01). Prothrombin time (PT) was unaffected by centrifugation times of less than 15 min. The changes in fibrinogen and aPTT when centrifugation time was decreased to less than 2 and 1 min, respectively, were clinically relevant.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
Cell count/volumeHematology/ auto analyzerMorphologyHematology/ auto analyzerGlycoproteinHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Aliquot sequential collection 1st collection2nd collection3rd collection4th collection5th collectionBiospecimen Aliquots and Components Centrifugation Multiple durations compared