Influence of blood collection techniques on platelet function.
Mani H, Kirchmayr K, Kläffling C, Schindewolf M, Luxembourg B, Linnemann B, Lindhoff-Last E
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of using a butterfly cannula system as opposed to a straight needle on platelet function. Both the butterfly device and straight needle were 21-gauge. Platelet-rich plasma was used for analysis on the automated BCT and the manual aggregometer PAP-4 while anticoagulated whole blood was used for analysis on the PFA-100.
Summary of Findings
Neither platelet aggregation response measured by the BCT or the PAP-4, nor CT measured by the PFA-100 were significantly different between specimens collected using a butterfly device and those collected using a straight needle, regardless of which aggregation inducer was used.
Biospecimens
FluidBloodFluidPlasmaPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
Cell count/volumeHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Method of fluid acquisition Butterfly deviceNeedleHematology/ auto analyzer Specific Reaction solution ADPArachidonic acidCollagenCollagen/ADPCollagen/epinephrineHematology/ auto analyzer Specific Technology platform BCT (automated)PAP-4 (manual)PFA-100