Skip to main content

The order of draw of blood specimens into additive containing tubes not affect potassium and calcium measurements.

Majid A, Heaney DC, Padmanabhan N, Spooner R

Publication: J Clin Pathol (1996) • Vol 49 • Page 1019-20PMID: 9038745View on PubMed

Purpose

The purpose of this paper was to determine the effects of draw order on levels of potassium and calcium in serum.

Conclusion

There were no significant differences in potassium or calcium levels in serum collected immediately after venipuncture or from a third sequential collection (following collection of blood into a potassium-EDTA Vacutainer).

Studies (1)

Purpose

The purpose of this study was to determine the effects of draw order on levels of potassium and calcium in serum. Three specimens were collected from a single venipuncture into Vacutainers containing no anticoagulant, potassium-EDTA, and no anticoagulant, in that order. Potassium and calcium levels were compared between the first and third collections.

Summary of Findings

There were no significant differences in potassium or calcium levels in serum collected immediately after venipuncture or from a third sequential collection (following collection of blood into a potassium-EDTA Vacutainer). Specimens from one patient, obtained after a difficult venipuncture, had analyte levels more than 5 standard deviations away from the averages and consequently were excluded from analysis.

  • Biospecimens

    FluidSerum
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Electrolyte/MetalClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsAliquot sequential collection
    1st collection
    3rd collection