The purpose of this study was to determine the effects of draw order on levels of potassium and calcium in serum. Three specimens were collected from a single venipuncture into Vacutainers containing no anticoagulant, potassium-EDTA, and no anticoagulant, in that order. Potassium and calcium levels were compared between the first and third collections.
Summary of Findings
There were no significant differences in potassium or calcium levels in serum collected immediately after venipuncture or from a third sequential collection (following collection of blood into a potassium-EDTA Vacutainer). Specimens from one patient, obtained after a difficult venipuncture, had analyte levels more than 5 standard deviations away from the averages and consequently were excluded from analysis.
Biospecimens
FluidSerumFluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
Electrolyte/MetalClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Aliquot sequential collection 1st collection3rd collection