Skip to main content

Plasma tissue inhibitor of metalloproteinases-1 as a biological marker? Pre-analytical considerations.

Lomholt AF, Frederiksen CB, Christensen IJ, Brünner N, Nielsen HJ

Publication: Clin Chim Acta (2007) • Vol 380 • Page 128-32PMID: 17328880View on PubMed

Purpose

The purpose of this paper was to determine the effects of tourniquet use during collection, precentrifugation whole blood storage temperature, centrifugation speed and temperature, and cellular contamination on the levels of Tissue Inhibitor of Metalloproteinases-1 (TIMP-1) in plasma.

Conclusion

Centrifugation speed and temperature and tourniquet use had no effects on TIMP-1 levels in plasma. However, contamination of plasma with the 5 mM of plasma closest to the buffy coat significantly increased TIMP-1 levels. Storing whole blood at room temperature prior to centrifugation, as opposed to on ice, also resulted in significantly higher levels of TIMP-1 in plasma.

Studies (1)

Purpose

The purpose of this study was to determine the effects of tourniquet use during collection, precentrifugation whole blood storage temperature, centrifugation speed (2500 x g, 3000 x g or 3500 x g)  and temperature (room temperature or 4 degrees C), and cellular contamination on the levels of TIMP-1 in plasma. All plasma was frozen at -80 degrees C for at least 48 h prior to analysis.

Summary of Findings

Centrifugation speed and the use of a tourniquet for 2 min as opposed to no tourniquet during collection had no effects on TIMP-1 levels. Contamination of plasma with the 5 mM of plasma closest to the buffy coat significantly increased TIMP-1 levels (p<0.0001), and TIMP-1 levels were significantly correlated with beta-thromboglobulin (beta-TG) levels in contaminated tubes (r=0.75) but not in uncontaminated tubes (r=0.06). There were no significant differences in TIMP-1 levels between the lower, middle, and upper thirds of supernatant plasma after centrifugation, provided that the lowest 5 mM near the buffy coat was not evaluated. Storing whole blood at room temperature prior to centrifugation, as opposed to on ice, resulted in significantly higher levels of TIMP-1 (p<0.0001), but centrifugation temperature had no significant effects on TIMP-1 levels.

  • Biospecimens

    FluidPlasma
    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    Not specified
    Normal
  • Platforms

    ProteinELISA
    ProteinImmunoassay
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionMethod of fluid acquisition
    Tourniquet times compared
    Biospecimen Aliquots and ComponentsBiospecimen components
    Lower third of supernatant (plasma)
    Middle third of supernatant (plasma)
    Plasma added from 5 mM closest to buffy coat
    Plasma from 5 mM and higher above buffy coat
    Upper third of supernatant (plasma)
    Biospecimen Aliquots and ComponentsBlood and blood products
    Multiple sampling positions examined
    Plasma
    Whole blood
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    Multiple speeds compared
    Multiple temperatures compared
    StorageStorage temperature
    On ice
    Room temperature