Skip to main content

Influence of the needle bore size used for collecting venous blood samples on routine clinical chemistry testing.

Lippi G, Salvagno GL, Montagnana M, Brocco G, Cesare Guidi G

Publication: Clin Chem Lab Med (2006) • Vol 44 • Page 1009-14PMID: 16879070View on PubMed

Purpose

The purpose of this paper was to determine the effects of needle gauge on 14 common clinical chemistry analytes and free hemoglobin levels in serum.

Conclusion

With specimens collected using a 21-gauge needle used as a reference, levels of none of the 14 clinical chemistry analytes or free hemoglobin showed changes greater than the reported analytical quality specifications for desirable bias when specimens were collected using 23- or 25-gauge needles.

Studies (1)

Purpose

The purpose of this study was to determine the effects of needle gauge on 14 common clinical chemistry analytes and free hemoglobin levels in serum. Three sequential venipunctures, on alternating arms and different veins, were used to collect specimens within 5 min.

Summary of Findings

With specimens collected using a 21-gauge needle used as a reference, levels of none of the 14 clinical chemistry analytes or free hemoglobin showed changes greater than the reported analytical quality specifications for desirable bias when specimens were collected using 23- or 25-gauge needles. Lower correlation coefficients were observed between specimens collected using a 21-gauge needle and those collected using a 23- or 25-gauge needle for electrolytes including calcium, chloride, potassium, and sodium.

  • Biospecimens

    FluidSerum
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    ProteinClinical chemistry/auto analyzer
    Electrolyte/MetalClinical chemistry/auto analyzer
    Small moleculeClinical chemistry/auto analyzer
    CarbohydrateClinical chemistry/auto analyzer
    ProteinSpectrophotometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionNeedle gauge
    21-gauge
    23-gauge
    25-gauge
    Biospecimen Aliquots and ComponentsAliquot sequential collection
    1st collection
    2nd collection
    3rd collection