Influence of the needle bore size on platelet count and routine coagulation testing.
Lippi G, Salvagno GL, Montagnana M, Poli G, Guidi GC
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of needle gauge on platelet counts, PT, APTT, and fibrinogen, D-dimer, and free hemoglobin levels in plasma. Three sequential venipunctures, on alternating arms and different veins, were used to collect specimens within 5 min.
Summary of Findings
With specimens collected using a 21-gauge needle used as a reference, D-dimer levels were significantly higher when blood was collected using a 25-gauge needle (p<0.001), and platelet counts were significantly lower when collected using a 23-gauge or 25-gauge needle (both p<0.001). No significant differences were seen between 21-gauge needle specimens and 23-gauge or 25-gauge needle specimens with respect to APTT, PT, fibrinogen, or free hemoglobin.
Biospecimens
FluidPlasmaFluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
PeptideELISAMorphologyHematology/ auto analyzerGlycoproteinHematology/ auto analyzerCell count/volumeHematology/ auto analyzerProteinSpectrophotometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Needle gauge 21-gauge23-gauge25-gaugeBiospecimen Aliquots and Components Aliquot sequential collection 1st collection2nd collection3rd collection