Hemolysis in Serum Samples Drawn by Emergency Department Personnel versus Laboratory Phlebotomists
Burns ER, Yoshikawa N
Purpose
Conclusion
Studies (2)
Purpose
The purpose of this study was to retrospectively determine the factors associated with increased rates of hemolysis in serum from blood specimens drawn in the emergency department compared to those obtained in the medical ward.
Summary of Findings
Retrospective analysis of 4,021 blood specimens collected in the emergency department or the medical floor revealed that 12.4% of the emergency department drawn specimens were hemolyzed and 1.6% of the medical floor drawn specimens were hemolyzed (p>0.0001). The specimens drawn in the emergency department were more likely to be obtained by staff that were not formally trained or certified in phlebotomy, drawn using plastic catheters and venipuncture sites distal to the antecubital fossa, and transported via pneumatic tube. The medical floor drawn specimens were more likely to be obtained by trained and certified phlebotomists, drawn using straight metal needles and butterflies with venipuncture sites in the antecubital fossa, and transported to the laboratory by hand.
Biospecimens
FluidSerumFluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
Cell count/volumeSpectrophotometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anatomical location of blood draw Anticubital veinDistal veinBiospecimen Acquisition Locale of biospecimen collection Emergency departmentMedical wardBiospecimen Acquisition Method of fluid acquisition Butterfly deviceIV catheterNeedleStaff trained/experienced in phlebotomyStaff untrained/inexperienced in phlebotomyStorage Within hospital transportation method Hand-deliveredPneumatic tube system
Purpose
The purpose of this study was to determine the phlebotomy parameters that cause significantly higher rates of hemolysis in serum specimens. All blood specimens were obtained in the emergency department by nurses or technicians that were uncertified in phlebotomy and transported via pneumatic tube transport.
Summary of Findings
Hemolysis rates were significantly higher when blood was drawn through 22-gauge plastic catheters than through 20-gauge plastic catheters (p=0.0123), but hemolysis rates in specimens drawn using any plastic catheter were higher than those drawn using metal straight needles or butterflies (p=0.0164). Hemolysis rates were also higher when venipuncture site was distal to the antecubital fossa rather than in the antecubital fossa (p=0.0054), and when tubes were filled less than half-way (p=0.0159). The use of extension tubing or syringes during blood collection did not affect the rates of hemolysis. The authors state that the use of tourniquet compression for more than 2 min versus 2 min or less increased hemolysis rates. The phlebotomy parameters with the greatest contribution to increased rates of hemolysis were drawing from a vein in the distal arm and underfilling the tube, in that order.
Biospecimens
FluidSerumFluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
Cell count/volumeSpectrophotometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anatomical location of blood draw Anticubital veinDistal veinBiospecimen Acquisition Cannulation 20-gauge plastic catheter22-gauge plastic catheterBiospecimen Acquisition Method of fluid acquisition Butterfly deviceExtension tubingIV catheterNeedleNo extension tubingSyringe drawTourniquet times comparedBiospecimen Aliquots and Components Aliquot size/volume <1/2 full tube>1/2 full tube