Examination of stability of bone marrow blood RNA in the PAXgene tube.

Yamamoto T, Sekiyama A, Sekiguchi H, Yoshida T, Miyagi Y

Publication: Lab Hematol (2006) • Vol 12 • Page 143-7PMID: 16950675View on PubMed

Purpose

The purpose of this paper was to determine the effects of preservation with PAXgene and refrigerated storage on RNA yield, integrity, and amplification success of bone marrow blood specimens from leukemia patients in remission.

Conclusion

RNA yield from bone marrow blood decreased with increasing refrigerated storage in EDTA or PAXgene tubes and was lower in unstored PAXgene specimens than unstored EDTA specimens. In specimens from one patient, the 28S ribosomal RNA (rRNA) band was of lower intensity in PAXgene specimens stored 3 or 5 days than any EDTA specimens, regardless of storage time. In contrast the intensity of the 18S rRNA band was higher in the PAXgene specimens stored for 3 or 5 days than in any EDTA specimens. On average, bone marrow blood stored in PAXgene tubes for 3 or 5 days had higher concentrations of porphobilinogen deaminase (PBGD) transcripts than bone marrow blood collected in EDTA tubes and not stored. Further, breakpoint cluster region (BCR)-V-abl Abelson murine leukemia viral oncogene homolog 1 (ABL) fusion transcripts were detected at low levels in specimens from one patient stored in PAXgene tubes but not in specimens from the same patient stored in EDTA tubes for 3 or 5 days. In contrast, average Wilm's tumor suppressor (WT1) transcript levels were lower in PAXgene specimens stored for 3 or 5 days than in unstored EDTA specimens, but levels remained relatively stable with storage.

Studies (1)

Purpose

The purpose of this study was to determine the effects of preservation with PAXgene and refrigerated storage on RNA yield, integrity, and amplification success of bone marrow blood specimens from leukemia patients in remission. Bone marrow blood was collected from 9 individuals into EDTA tubes, and blood cells were transferred immediately to EDTA and PAXgene tubes and stored at 4 degrees C until analysis on days 0, 3, and 5. RNA extraction was with trizol.

Summary of Findings

RNA yield from bone marrow blood decreased with increasing refrigerated storage in EDTA or PAXgene tubes. On day 0, the RNA yield was lower from PAXgene specimens than EDTA specimens and the decrease in RNA yield was much faster between days 0 and 3 when stored in PAXgene tubes rather than EDTA tubes. After day 3, the rate of decrease in RNA yield in PAXgene tubes was slightly less than that in EDTA tubes. In specimens from a single patient, the 28S rRNA band was of lower intensity in the PAXgene specimens stored 3 or 5 days than any of the EDTA specimens, regardless of storage. Further, the intensity tended to decrease for PAXgene and EDTA specimens with increasing storage time. In contrast, the intensity of the 18S rRNA band was higher in the PAXgene specimens stored for 3 or 5 days than in any EDTA specimens, regardless of storage time. On average, bone marrow blood stored in PAXgene tubes for 3 or 5 days had a higher concentration of PBGD transcripts than unstored bone marrow blood in EDTA tubes. Further, BCR-ABL was detected at low levels in specimens from a single patient stored in PAXgene but was not detected in specimens stored in EDTA tubes. In contrast, average Wilm's tumor suppressor WT1 levels were lower in PAXgene specimens stored 3 or 5 days than in unstored EDTA specimens, but levels remained relatively stable with storage.

  • Biospecimens

    FluidBlood
    CellBlood
    FluidBone Marrow
  • Preservation Types

    None (Fresh)PAXgene
  • Diagnoses

    NeoplasticLeukemia
  • Platforms

    RNASpectrophotometry
    RNAReal-time qRT-PCR
    RNAElectrophoresis
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationType of fixation/preservation
    None (fresh)
    PAXgene
    Refrigeration
    StorageStorage duration
    0 days
    3 days
    5 days
    Real-time qRT-PCR SpecificTargeted nucleic acid
    BCR-ABL fusion
    PBGD
    WT1