Skip to main content

The influence of preanalytical factors on concentrations of morphine and metabolites in patients receiving morphine.

Westerling D, Bengtsson HI, Thysell C, Höglund P

Publication: Pharmacol Toxicol (1996) • Vol 78 • Page 82-5PMID: 8822039View on PubMed

Purpose

The purpose of this paper was to determine the effects of anticoagulant, blood component, whole blood storage, centrifugation temperature, frozen storage of plasma, and freeze-thaw cycling on measured levels of morphine and its metabolites.

Conclusion

Collection of blood into EDTA tubes, but not serum separator tubes (SST), resulted in an observed 4.8% increase in morphine levels compared to those found in heparinated specimens. When blood was stored at 37 degrees C, prior to centrifugation, observed morphine levels were 4.4% higher than when stored at 0 degrees C, regardless of storage duration. Centrifugation temperature, frozen storage of plasma, and freeze-thaw cycling did not significantly affect measured morphine levels. The authors report no effect of the tested conditions on the measurement of the morphine metabolites morphine-3-glucuronide (M3G) or morphine-6-glucuronide (M6G).

Studies (1)

Purpose

The purpose of this study was to determine the effects of anticoagulant, blood component, whole blood storage, centrifugation temperature (4°C, room temperature or not controlled), frozen storage of plasma, and freeze-thaw cycling on measured levels of morphine and its metabolites. After centrifugation, plasma was analyzed immediately, frozen at -25 degrees C and analyzed after 1 thaw, or frozen at -25 degrees C thawed for 24 h at room temperature and refrozen before thawing and analysis. Serum was collected in serum separator tubes (SST).

Summary of Findings

Collection of blood into K3EDTA tubes, but not SST, resulted in an observed 4.8% increase in morphine levels compared to those found in heparinated specimens. When blood was stored at 37 degrees C, prior to centrifugation, observed morphine levels were 4.4% higher than when stored at 0 degrees C, and there were no effects of increasing the storage duration from 15 min to 60 or 240 min. Further, centrifugation temperature, frozen storage of plasma, and freeze-thaw cycling did not significantly affect measured morphine levels. The authors report that anticoagulant, blood components, storage temperature and duration, centrifugation temperature and freeze-thaw cycling did not affect measured levels of the morphine metabolites M3G or M6G.

  • Biospecimens

    FluidPlasma
    FluidSerum
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Other diagnoses
  • Platforms

    Small moleculeHPLC
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Chronic pain patient
    Ear/nose/throat presurgical patient
    Biospecimen AcquisitionAnticoagulant
    None
    Potassium EDTA
    Sodium heparin
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Serum
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    Multiple temperatures compared
    StorageFreeze/thaw cycling
    0 cycles
    1 cycle
    2 cycles
    StorageStorage duration
    15 min
    240 min
    60 min
    StorageStorage temperature
    0 degrees C
    20 degrees C
    37 degrees C