The influence of the tourniquet time on hematological testing for antidoping purposes.
Lippi G, Salvagno GL, Solero GP, Guidi GC
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of tourniquet time and aliquot sequential collection on hemoglobin, hematocrit, and reticulocyte counts in blood specimens from professional athletes. The first and tenth blood specimens collected from a single venipuncture with tourniquet application were compared. The average length of tourniquet application was 2.30 +/- 0.12 min. The first specimen was collected at the commencement of tourniquet application while the 10th specimen was collected at the end.
Summary of Findings
Hematocrit and hemoglobin levels were significantly higher (+2.4% and +1.4%, respectively) in the 10th specimen (collected after a longer tourniquet application) than in the first specimen (both p<0.001). However, reticulocyte counts were not significantly different between the two specimens. 15% of specimens exceeded the desirable analytical quality total error specification of 4.1% for hematocrit.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
ProteinHematology/ auto analyzerCell count/volumeHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Method of fluid acquisition Tourniquet times comparedBiospecimen Aliquots and Components Aliquot sequential collection 10th collection1st collection