Assessment of two methods for handling blood in collection tubes with RNA stabilizing agent for surveillance of gene expression profiles with high density microarrays.

Thach DC, Lin B, Walter E, Kruzelock R, Rowley RK, Tibbetts C, Stenger DA

Publication: J Immunol Methods (2003) • Vol 283 • Page 269-79PMID: 14659918View on PubMed

Purpose

The purpose of this paper was to determine the effects of storing blood in PAXgene tubes at room temperature for 9 h followed by storage at -20 degrees C for 6 days rather than for 2 h at room temperature on the RNA transcriptome determined by microarray.

Conclusion

Specimens stored for 2 h at room temperature had higher RNA yield, but this was due to more DNA contamination than specimens stored at room temperature for 9 h followed by 6 days at -20 degrees C. On column DNAse treatment was not sufficient to remove DNA contamination, but use of in-solution DNAse was, as determined by real-time PCR amplification of Glyceraldehyde 3-phosphate dehydrogenase (GAPDH) in RNA. RNA purity and quality, cDNA and cRNA yield, cRNA purity and microarray quality metrics were not affected by storage duration. Analysis of variance (ANOVA) revealed that 99% of the variation in expression of 100 selected genes was based on gene, but 0.17% of the variation was determined by the microarray platform and 0.09% of the variation was determined by the storage duration of the specimen in the PAXgene tube.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storing blood in PAXgene tubes at room temperature for 9 h followed by -20 degrees C for 6 days rather than for 2 h at room temperature on the RNA transcriptome determined by microarray. After storage, RNA was extracted immediately, and RNA from specimens stored for 2 h was frozen until all samples could be analyzed.

Summary of Findings

Specimens stored for 2 h at room temperature had higher RNA yield, as determined by spectrophotometer (7.3 ug versus 6.3 ug, p=0.007), and more DNA contamination, as determined by real-time PCR of GAPDH, than the specimens stored for 9 h at room temperature followed by 6 days at -20 degrees C. After DNAse treatment, RNA yields were lower, as determined by integration of fluorescence (3.8 ug versus 4.7 ug, p=0.025), in specimens stored for 2 h at room temperature than in the specimens stored for 9 h at room temperature followed by 6 days at -20 degrees C. On column DNAse treatment was not sufficient to remove DNA contamination, but use of in-solution DNAse was, as determined by real-time PCR amplification of GAPDH in RNA. RNA purity and quality, cDNA and cRNA yield, cRNA purity and microarray quality metrics were not affected by storage duration. 99% of the variation in expression of 100 selected genes was based on gene (p<0.001), but 0.17% of the variation was determined by the microarray platform (HGU133a versus HGU133b, p<0.001) and 0.09% of the variation was determined by the storage duration of the specimen in the PAXgene tube (p<0.001), according to ANOVA.

  • Biospecimens

    FluidBlood
  • Preservation Types

    PAXgene
  • Diagnoses

    Not specified
  • Platforms

    DNAReal-time qPCR
    RNAAutomated electrophoresis/Bioanalyzer
    RNASpectrophotometry
    RNAReal-time qRT-PCR
    RNADNA microarray
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageTime at room temperature
    2 h
    9 h
    Analyte Extraction and PurificationNucleic acid digestion
    In-solution DNAse
    None
    On-column DNAse
    Real-time qRT-PCR SpecificTargeted nucleic acid
    GAPDH
    Real-time qPCR SpecificTargeted nucleic acid
    GAPDH
    DNA microarray SpecificTechnology platform
    HGU133a
    HGU133b