Influence of short-term venous stasis on clinical chemistry testing.

Lippi G, Salvagno GL, Montagnana M, Brocco G, Guidi GC

Publication: Clin Chem Lab Med (2005) • Vol 43 • Page 869-75PMID: 16201899View on PubMed

Purpose

The purpose of this paper was to determine the effects of venous stasis during blood draw on 12 common clinical chemistry analytes.

Conclusion

Of the 12 analytes tested, 7 (alanine aminotransferase (ALT), albumin, calcium, cholesterol, creatine kinase (CK), iron, and potassium) showed significant differences in the specimens obtained after 1 min stasis compared to those obtained with no venous stasis. After 3 min stasis during specimen collection, in addition to the 7 analytes mentioned above, chloride, creatinine, and glucose were also significantly different compared to levels found in specimens collected with no venous stasis. Urea nitrogen and sodium levels were not significantly affected by the use of a sphygmomanometer, for 1 or 3 min, during specimen collection.

Studies (1)

Purpose

The purpose of this study was to determine the effects of venous stasis during blood draw on 12 common clinical chemistry analytes. Three separate venipunctures were performed using three separate veins and alternating arms. The specimen without venous stasis was obtained first, followed by a specimen obtained while the volunteer had standardized pressure applied from a sphygmomanometer for 1 minute, and lastly, a specimen was obtained while the same pressure was applied for 3 minutes. Plasma was frozen at -70 degrees C until analysis.

Summary of Findings

Of the 12 analytes tested, 7 showed significant differences in the specimens obtained after 1 min stasis compared to those obtained with no venous stasis. The average levels of ALT, albumin, calcium, cholesterol, CK, and iron were higher after 1 min stasis, while the average potassium levels were lower compared to specimen collected with no venous stasis. After 3 min stasis during specimen collection, in addition to the 7 analytes mentioned above, average chloride and glucose levels were significantly lower, and average levels of creatinine were significantly higher than levels found in specimens collected with no venous stasis. Urea nitrogen and sodium levels were not significantly affected by the use of a sphygmomanometer, for 1 or 3 min, during specimen collection.

  • Biospecimens

    FluidPlasma
    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    Not specified
  • Platforms

    CarbohydrateClinical chemistry/auto analyzer
    Electrolyte/MetalClinical chemistry/auto analyzer
    ProteinClinical chemistry/auto analyzer
    Small moleculeClinical chemistry/auto analyzer
    SteroidClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionMethod of fluid acquisition
    Tourniquet times compared