The effect of the order of filling tubes after venipuncture on serum potassium, total protein, and aspartate and alanine aminotransferases.

Leppänen E, Gräsbeck R

Publication: Scand J Clin Lab Invest (1986) • Vol 46 • Page 189-91PMID: 3715371View on PubMed

Purpose

The purpose of this paper was to determine the effects of aliquot sequential collection on serum potassium (K), total protein, aspartate aminotransferase (ASAT), and alanine aminotransferase (ALAT) levels.

Conclusion

Serum protein, ASAT, and ALAT concentrations were not significantly different between the first 10 mL blood specimen drawn and the last 10 mL blood specimen drawn from the same venipuncture. However, serum K was significantly higher in the first 10 mL aliquot than the last 10 mL aliquot and in the first 1 mL blood aliquot compared to the 2nd aliquot consisting of a full 10 mL. Importantly, these differences were similar to the precision of the equipment used for the K measurements bringing clinical significance into question.

Studies (1)

Purpose

The purpose of this study was to determine the effects of aliquot sequential collection (from a single venipuncture) on serum K, total protein, ASAT, and ALAT measurements. The first and last tubes collected were compared, with the last tube being anywhere from the 2nd tube to the 11th tube. Tourniquets were not used. The authors do not specify whether serum was analyzed immediately or stored.

Summary of Findings

Serum protein, ASAT, and ALAT concentrations were not significantly different between the first 10 mL blood specimen drawn and the last 10 mL blood specimen drawn from the same venipuncture. However, serum K was significantly higher in the first 10 mL aliquot than the last 10 mL aliquot (+0.09 mmol/L, p<0.001). Further, serum K was significantly higher in the first 1 mL blood aliquot compared to the 2nd aliquot consisting of 10 mL (+0.08 mmol/L, p<0.001). Importantly, these differences were similar to the precision of the equipment used for the K measurements bringing clinical significance into question.

  • Biospecimens

    FluidSerum
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Electrolyte/MetalFlame emission photometry
    ProteinClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsAliquot sequential collection
    1st collection
    Not first collection
    Biospecimen Aliquots and ComponentsAliquot size/volume
    1 mL
    10 mL