Real time-PCR assay estimating the naive T-cell pool in whole blood and dried blood spot samples: pilot study in young adults.
Lang PO, Mitchell WA, Govind S, Aspinall R
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of using DNA from PBMC versus DBS for the calculation of sj-TREC and T-cells counts via real time qPCR and flow cytometric analysis. Isolated PBMC were stored at -80 C until DNA extraction while DBS were stored desiccated at -20 degrees C.
Summary of Findings
Leukocyte counts and sj-TREC/T-cells ratios were comparable when calculated by qPCR analysis or measured by flow cytometry. Further, both DNA extracted from PBMC and from DBS fell into an acceptable purity range, and qPCR results using DNA from each specimen type were not significantly different.
Biospecimens
FluidBloodCellBloodPreservation Types
FrozenOther PreservativeDiagnoses
NormalPlatforms
Cell count/volumeFlow cytometryDNAReal-time qPCRDNASpectrophotometryCell count/volumeReal-time qPCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Preservation Type of fixation/preservation Air-driedFrozenReal-time qPCR Specific Targeted nucleic acid AlbuminVD junction of T-cell receptor-betasj-TRECFlow cytometry Specific Technology platform Real time qPCR