A comparison of hemolysis rates using intravenous catheters versus venipuncture tubes for obtaining blood samples.
Kennedy C, Angermuller S, King R, Noviello S, Walker J, Warden J, Vang S
Purpose
The purpose of this paper was to determine the effects of collection method and intravenous (IV) catheter diameter on blood hemolysis rates.
Conclusion
Hemolysis rates were higher in specimens obtained by IV catheter (13.7%) than by Vacutainer venipuncture (3.8%), but blood specimens were unable to be obtained by venipuncture in 7 of 85 patients. Hemolysis rates were increased in specimens obtained with higher gauge catheters (smaller diameters).
Studies (1)
Purpose
The purpose of this study was to determine the effects of using venipuncture versus IV catheter for specimen collection and IV catheter diameter on blood hemolysis rates in specimens from emergency department patients.
Summary of Findings
Hemolysis rates were higher in specimens obtained by IV catheter (13.7%) than by Vacutainer venipuncture (3.8%), but blood specimens were unable to be obtained by venipuncture in 7 of 85 patients. Hemolysis rates were increased in specimens obtained with higher gauge catheters (smaller diameters) (p=0.047), however, sample size was variable for each catheter gauge with only 1 and 4 specimens obtained using 24 gauge (100% hemolysis) and 22 gauge (25% hemolysis) catheters, respectively, while 39 and 40 specimens were obtained using 20 gauge (15% hemolysis) and 18 gauge (10% hemolysis) catheters, respectively.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
Cell count/volumeMacroscopic observationPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Cannulation 14 gauge catheter16 gauge catheter18 gauge catheter20 gauge catheter22 gauge catheter24 gauge catheterBiospecimen Acquisition Method of fluid acquisition IV catheterVenipuncture