Pre-analytical variation in the measurements of sensitive markers of coagulation and fibrinolysis: the influence of venipuncture and mixing of blood.

Iversen LH

Publication: Haemostasis (1997) • Vol 27 • Page 119-24PMID: 9306128View on PubMed

Purpose

The purpose of this paper was to determine the effects of experience level of the technologist collecting blood and mixing procedure on coagulation and fibrinolysis markers in plasma.

Conclusion

Specimens collected by inexperienced technologists (surgical trainees) had on average 21%, 277%, 28%, and 6% higher levels of prothrombin fragment 1+2 (F1+2), thrombin-antithrombin complex (TAT), soluble fibrin (SF), and total fibrinogen degradation products (TDP), respectively, than specimens collected by experiences technologists. The differences between F1+2 and TAT were significant. Inverting tubes twice, as opposed to 5 times, or delaying the inversion by 3 minutes did not affect analyte values.

Studies (1)

Purpose

The purpose of this study was to determine the effects of experience level of the technologist collecting blood and mixing procedure on coagulation and fibrinolysis markers in plasma from colorectal cancer patients and healthy volunteers. Two surgical trainees served as the inexperienced technologists and were compared to 1 experienced technologist. Citrated plasma was aliquoted and stored at -80 degrees C for up to 1 week prior to analysis.

Summary of Findings

Specimens collected by inexperienced technologists (surgical trainees) had on average 21%, 277%, 28%, and 6% higher levels of F1+2, TAT, SF, and TDP, respectively, than specimens collected by experiences technologists. The differences between F1+2 and TAT were significant. Exclusion of 2 of 20 cases ruled out the significance of the difference in F1+2 values. Calculating the significance based on 10 measurements for each of two inexperienced technologists (rather than combined) eliminated the significance of the differences between TAT values in specimens obtained by one, but not the other inexperienced technologist versus the experienced technologist. Inverting tubes twice, as opposed to 5 times, or delaying the inversion by 3 minutes (at 20 degrees C) did not affect analyte values.

  • Biospecimens

    FluidPlasma
    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
    NeoplasticCarcinoma
  • Platforms

    ProteinELISA
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionMethod of fluid acquisition
    Staff trained/experienced in phlebotomy
    Staff untrained/inexperienced in phlebotomy
    Biospecimen Aliquots and ComponentsBiospecimen mixing
    Inverted 2 times
    Inverted 5 times
    Inverted 5 times after 3 min delay