Pre-analytical variation in the measurements of sensitive markers of coagulation and fibrinolysis: the influence of venipuncture and mixing of blood.
Iversen LH
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of experience level of the technologist collecting blood and mixing procedure on coagulation and fibrinolysis markers in plasma from colorectal cancer patients and healthy volunteers. Two surgical trainees served as the inexperienced technologists and were compared to 1 experienced technologist. Citrated plasma was aliquoted and stored at -80 degrees C for up to 1 week prior to analysis.
Summary of Findings
Specimens collected by inexperienced technologists (surgical trainees) had on average 21%, 277%, 28%, and 6% higher levels of F1+2, TAT, SF, and TDP, respectively, than specimens collected by experiences technologists. The differences between F1+2 and TAT were significant. Exclusion of 2 of 20 cases ruled out the significance of the difference in F1+2 values. Calculating the significance based on 10 measurements for each of two inexperienced technologists (rather than combined) eliminated the significance of the differences between TAT values in specimens obtained by one, but not the other inexperienced technologist versus the experienced technologist. Inverting tubes twice, as opposed to 5 times, or delaying the inversion by 3 minutes (at 20 degrees C) did not affect analyte values.
Biospecimens
FluidPlasmaFluidBloodPreservation Types
FrozenDiagnoses
NormalNeoplasticCarcinomaPlatforms
ProteinELISAPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Method of fluid acquisition Staff trained/experienced in phlebotomyStaff untrained/inexperienced in phlebotomyBiospecimen Aliquots and Components Biospecimen mixing Inverted 2 timesInverted 5 timesInverted 5 times after 3 min delay