Effects of electron-beam irradiation on buccal-cell DNA.
Castle PE, Garcia-Closas M, Franklin T, Chanock S, Puri V, Welch R, Rothman N, Vaught J
Purpose
Conclusion
Studies (1)
Purpose
The aim of this study was to assess possible effects associated with electron-beam irradiation of buccal cells on the yield, integrity, and amplification of extracted DNA. Buccal cells were collected via mouthwash expectoration from 32 volunteers. Three specimens were left untreated and were shipped, while the 27 remaining specimens were divided into two equal aliquots that were left untreated or subjected to 70-97 kilograys (KGy) of electron-beam irradiation, simulating an exposure of 56 KGy or greater that is used by the United States Postal Service in select zip codes. The authors do not specify how these 27 specimens were returned to the biorepository for analysis. Unopened bottles of mouthwash served as an additional control for some analyses. Buccal cells were pelleted from specimens immediately and cell pellets were stored between -70 and -80 degrees C until DNA extraction.
Summary of Findings
All irradiated samples, both buccal specimens and unopened bottles of mouthwash, exhibited a marked change in color from green to light brown and an increase in temperature immediately following irradiation, which were not observed among non-irradiated specimens that were mailed or otherwise returned to the biorepository. DNA yields of irradiated specimens were significantly reduced by approximately 50% compared to untreated specimens as quantified by spectrophotometry (p=0.002), PicoGreen assay (p=0.01), and Taqman assay for breast cancer type 1 (BRCA1)(p<0.0005). DNA purity was modestly elevated in irradiated specimens compared to untreated controls (1.74 versus 1.67 260/280 OD ratio, respectively; p=0.07). Genomic integrity was compromised by buccal cell irradiation, as the maximum size of genomic DNA observable in the majority of specimens (65-93%) by gel electrophoresis was 6,557 bp in irradiated specimens compared to 23,130 bp or greater in untreated specimens. PCR amplification efficiency of large (989 bp) beta-globin amplicons was also significantly reduced by specimen irradiation (p<0.0005), as 97% of irradiated specimens generated a weak positive while 93% of untreated specimens produced a strong positive. Amplification efficiencies for shorter amplicons (268 and 536 bp) were identical among irradiated and untreated specimens. While the authors report no significant differences in SNP detection rates between differentially treated specimens, data was not shown. Linear regression modeling of failure rates for the 16 STRs assessed revealed impacts of specimen irradiation (p=0.08) and fragment size (p<0.0005, which ranged between 112-359 bp), and an interaction between specimen irradiation and fragment size (p=0.01).
Biospecimens
CellBuccalFluidSalivaPreservation Types
FrozenDiagnoses
Not specifiedPlatforms
DNASpectrophotometryDNAReal-time qPCRDNAElectrophoresisDNAPCRDNASNP assayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Between site transportation method MailedUnspecified transport methodStorage Specimen transport duration/condition IrradiatedNon-irradiatedPCR Specific Length of gene fragment 268 bp536 bp989 bpPCR Specific Targeted nucleic acid Beta-globinReal-time qPCR Specific Targeted nucleic acid BRCA1