Quantification of relative changes in specific mRNAs from frozen whole blood - methodological considerations and clinical implications.

Øvstebø R, Lande K, Kierulf P, Haug KB

Publication: Clin Chem Lab Med (2007) • Vol 45 • Page 171-6PMID: 17311503View on PubMed

Purpose

The purpose of this paper was to determine the effects of preservation of blood with Paxgene, specimen storage temperature, template modification, and lipopolysaccharide (LPS) stimulation of whole blood on gene expression.

Conclusion

RNA yield, integrity and relative levels in LPS-stimulated blood, compared to unstimulated blood, were not significantly different between specimens that were immediately lysed in EasyLyse or stored for an unspecified time, in Paxgene, at room temperature or -70 degrees C, prior to lysis. The interindividual variability in mRNA levels in LPS-stimulated blood, relative to unstimulated blood, was much larger than that in a single specimen, sampled 9 times in 9 months, and stored in Paxgene tubes at -70 degrees C. Globin reduction did not generally improve real-time PCR results.

Studies (1)

Purpose

The purpose of this study was to determine the effects of preservation of blood with Paxgene, specimen storage temperature, globin reduction, and LPS stimulation of whole blood on mRNA levels measured by real-time PCR, using low-density arrays and standard 96-well plates. Blood was collected into EndoTubes and half was stimulated with LPS prior to immediate lysis in EasyLyse tubes or storage in Paxgene tubes, while the other half was unstimulated, but stored in the same two manners. Lysates were stored at -70 degrees C prior to RNA extraction and analysis.

Summary of Findings

RNA yield and RNA integrity numbers were not significantly different between specimens that were immediately lysed in EasyLyse or stored for an unspecified time, in Paxgene preservative, at room temperature or -70 degrees C, prior to lysis. Further, only small differences in the mRNA levels in LPS-stimulated blood, relative to unstimulated blood, were observed between the EasyLyse and Paxgene specimens from a single donor, and the mean differences were insignificant. There was a high degree of interindividual variability (1.6-8.5 fold changes) in mRNA levels in LPS-stimulated blood, relative to unstimulated blood, stored in Paxgene tubes at -70 degrees C, but this was not investigated in EasyLyse blood. When specimens were stored in Paxgene and sampled 9 times during 9 months at -70 degrees C, the differences between measurements were small compared to the inter-individual variability, but they were large enough that more than 10 replicates would be necessary to detect changes of 20% in interleukin (Il)-6, Il-18, CASP8 and FADD-like apoptosis regulator (CFLAR), Tumor necrosis factor superfamily member 10 (TNFSF10), heat shock 70 kDa protein 1B (HSPA1B) or beta-actin mRNA levels. Globin was successfully reduced to 1/100 of initial levels using the globin reduction protocol, but reduction of globin did not generally improve real-time PCR results.

  • Biospecimens

    FluidBlood
  • Preservation Types

    PAXgeneNone (Fresh)
  • Diagnoses

    Normal
  • Platforms

    RNAAutomated electrophoresis/Bioanalyzer
    RNAReal-time qRT-PCR
    RNALow density array
    RNASpectrophotometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsBiospecimen components
    With LPS stimulation
    Without LPS stimulation
    Biospecimen PreservationType of fixation/preservation
    None (fresh)
    PAXgene
    StorageStorage temperature
    -70 degrees C
    Room temperature
    Low density array SpecificTargeted nucleic acid
    Beta-actin
    CCL2
    CFLAR
    Factor III
    GAPDH
    HSPA1B
    Il-10
    Il-18
    Il-6
    Il-8
    TNF2
    TNFSF10
    Real-time qRT-PCR SpecificTargeted nucleic acid
    Beta-globin
    GAPDH
    Real-time qRT-PCR SpecificTemplate modification
    Globin reduced
    Unmodified