The effect of blood drawing techniques and equipment on the hemolysis of ED laboratory blood samples.

Grant MS

Publication: J Emerg Nurs (2003) • Vol 29 • Page 116-21PMID: 12660692View on PubMed

Purpose

The purpose of this paper was to determine the effects of phlebotomy technique on the degree of hemolysis in serum specimens.

Conclusion

Higher rates of hemolysis were observed when specimens were collected via new intravenous (IV) catheters versus straight needles, but IV catheter gauge did not significantly affect hemolysis rates. New IV catheter draws using a vacutainer had a significantly higher level of hemolysis than those collected using a syringe. High or gross levels of hemolysis were not observed in specimens that were drawn using a straight needle and either a vacutainer or syringe. The authors state that blood transfer method from a syringe (by needle directly to tube versus needleless connector to vacutainer and tube) had no effect on hemolysis rates.

Studies (1)

Purpose

The purpose of this study was to determine the effects of venipuncture technique (IV catheter versus straight needle), blood-draw method (vacutainer versus syringe), and blood-transfer method (needle to a tube versus needleless connector to a vacutainer and a tube) on the degree of hemolysis in serum specimens. The degree of hemolysis was determined by manual observation of serum color and graded on a 0-4 scale.

Summary of Findings

144/454 (32%) of specimens had some degree of hemolysis (level 1-4). 13% of specimens had high or gross hemolysis (graded at a 3-4 level) and were inappropriate for scheduled tests. 20% of specimens collected via new IV catheters (1st collection) were hemolyzed at high or gross levels while 10% of specimens collected via existing IV catheters and 1% of the specimens collected via straight needle had similar levels of hemolysis. The difference in hemolysis rates between new IV catheters and straight needles was significant (P<0.001). No significant differences were found in hemolysis rates between specimens collected using the different IV catheter gauges. Hemolysis rates among specimens collected using straight needles were too low to assess the effects of needle gauge. The authors state that syringe size had no effect on hemolysis rates. New IV catheter draws using a vacutainer had a significantly higher level of hemolysis than those collected using a syringe (P=0.02). High or gross levels of hemolysis were not observed when specimens were drawn using a straight needle and either a vacutainer or syringe. The authors state that blood transfer method from a syringe (by needle directly to tube versus needleless connector to vacutainer and tube) had no effect on hemolysis rates.

  • Biospecimens

    FluidSerum
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Cell count/volumeMacroscopic observation
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionCannulation
    14 gauge catheter
    16 gauge catheter
    18 gauge catheter
    20 gauge catheter
    Biospecimen AcquisitionMethod of fluid acquisition
    Central venous catheter
    IV catheter
    Needle
    Needleless connector
    Syringe draw
    Vacuum tube
    Venipuncture
    Biospecimen AcquisitionNeedle gauge
    21 gauge
    22 gauge
    23 gauge
    Biospecimen AcquisitionType of collection container/solution
    10 mL syringe
    20 mL or higher syringe
    5 mL syringe
    Biospecimen Aliquots and ComponentsAliquot sequential collection
    1st collection
    Not first collection