The effect of blood drawing techniques and equipment on the hemolysis of ED laboratory blood samples.
Grant MS
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of venipuncture technique (IV catheter versus straight needle), blood-draw method (vacutainer versus syringe), and blood-transfer method (needle to a tube versus needleless connector to a vacutainer and a tube) on the degree of hemolysis in serum specimens. The degree of hemolysis was determined by manual observation of serum color and graded on a 0-4 scale.
Summary of Findings
144/454 (32%) of specimens had some degree of hemolysis (level 1-4). 13% of specimens had high or gross hemolysis (graded at a 3-4 level) and were inappropriate for scheduled tests. 20% of specimens collected via new IV catheters (1st collection) were hemolyzed at high or gross levels while 10% of specimens collected via existing IV catheters and 1% of the specimens collected via straight needle had similar levels of hemolysis. The difference in hemolysis rates between new IV catheters and straight needles was significant (P<0.001). No significant differences were found in hemolysis rates between specimens collected using the different IV catheter gauges. Hemolysis rates among specimens collected using straight needles were too low to assess the effects of needle gauge. The authors state that syringe size had no effect on hemolysis rates. New IV catheter draws using a vacutainer had a significantly higher level of hemolysis than those collected using a syringe (P=0.02). High or gross levels of hemolysis were not observed when specimens were drawn using a straight needle and either a vacutainer or syringe. The authors state that blood transfer method from a syringe (by needle directly to tube versus needleless connector to vacutainer and tube) had no effect on hemolysis rates.
Biospecimens
FluidSerumFluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
Cell count/volumeMacroscopic observationPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Cannulation 14 gauge catheter16 gauge catheter18 gauge catheter20 gauge catheterBiospecimen Acquisition Method of fluid acquisition Central venous catheterIV catheterNeedleNeedleless connectorSyringe drawVacuum tubeVenipunctureBiospecimen Acquisition Needle gauge 21 gauge22 gauge23 gaugeBiospecimen Acquisition Type of collection container/solution 10 mL syringe20 mL or higher syringe5 mL syringeBiospecimen Aliquots and Components Aliquot sequential collection 1st collectionNot first collection