Skip to main content

Genotyping whole-genome-amplified DNA from 3- to 25-year-old neonatal dried blood spot samples with reference to fresh genomic DNA.

Hollegaard MV, Thorsen P, Norgaard-Pedersen B, Hougaard DM

Publication: Electrophoresis (2009) • Vol 30 • Page 2532-5PMID: 19639574View on PubMed

Purpose

The purpose of this paper was to determine the effects of storage duration, DNA extraction method, whole genome amplification (WGA) method, and reamplification on DNA yield and genotype calls using archived dried blood spots (DBS).

Conclusion

Extraction of DNA from the DBS was most efficient using the Extract-N-Amp (ENA) method, followed by the in-house chelex-100 method, and extraction was least efficient using the QIAamp kit. 100% call rates were achieved for DNA extracted using the in-house extraction method in combination with GPlex 2 or 4 (with or without reamplification), QIAamp extraction with GPlex 2 (without reamplification) or GPlex 4 (with reamplification), or ENA extraction with GPlex 4 (with or without reamplification) or GPlex 2 (with reamplification). 100% concordance of calls (with unamplified buccal cell DNA) was observed for all specimens extracted with the in- house method or ENA method, but this level of concordance was not reached for QIAamp-extracted specimens amplified with RepliG, AmpliQ, GPlex4 or GPLex3 with reamplification. The authors report storage duration of DBS did not impact genomic DNA yield, amplified DNA yield, call rates, or call accuracy.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storage duration, DNA extraction method, WGA method, and reamplification on DNA yield from archived DBS and genotype calls using MassArray. Concordance was determined between results from DBS and those from mailed, fresh buccal cells from the same volunteers (buccal cell DNA was unamplified). SNP calls were made in duplicate, and in the case of conflicting results, a null call was made. SNP genotyping was determined using a blind experimental design.

Summary of Findings

Extraction of DNA from the DBS was most efficient using the ENA method (64 ng DNA/disk), followed by the in-house chelex-100 method (36.2 ng DNA/disk), and extraction was least efficient using the QIAamp kit (14 ng DNA/disk). AmpliQ failed to amplify DNA extracted from DBS with the ENA kit. 100% call rates were achieved in DNA extracted using the in-house extraction method in combination with GPlex 2 or 4 (with or without reamplification), QIAamp extraction with GPlex 2 (without reamplification) or GPlex 4 (with reamplification), or ENA extraction with GPlex 4 (with or without reamplification) or GPlex 2 (with reamplification). 100% concordance of calls (with unamplified buccal cell DNA) was observed for all specimens extracted with the in-house method or ENA method, but this level of concordance was not reached for QIAamp-extracted specimens amplified with RepliG, AmpliQ, GPlex4 or GPLex3 with reamplification. The authors report storage duration of DBS did not impact genomic DNA yield, amplified DNA yield, call rates, or call accuracy.

  • Biospecimens

    FluidBlood
    CellBuccal
  • Preservation Types

    Other PreservativeNone (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    DNAFluorometry
    DNASNP assay
    DNAWhole genome amplification
    DNAMS/MS
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionBiospecimen location
    Blood
    Buccal cells
    Biospecimen PreservationType of fixation/preservation
    Air-dried
    None (fresh)
    StorageStorage duration
    11-15 years
    16-20 years
    21-25 years
    3-5 years
    6-10 years
    Analyte Extraction and PurificationAnalyte isolation method
    Extract-N-Amp Blood PCR kit
    In-house chelex-100 method
    QIAamp DNA blood mini kit
    Whole genome amplification SpecificNucleic acid amplification
    AmpliQ
    GenomePlex complete WGA (GPlex2)
    GenomePlex single cell WGA (GPlex4)
    None
    Reamplification with GenomePlex reamplification (GPlex3)
    RepliG